Maintenance

NOTE: Any service procedure not covered inthe
maintenance schedule should be performed by
qualified service personnel.
The air compressor should be turned off,unplugged
from the power source, air btedfrom the tank and
allowed time to cool before any maintenance is
performed.
To ensure efficient operation and longer life of the
air compressor unit, a routine maintenance schedule
shoutd be followed. The following schedule is geared
toward a consumer whose compressor is used iRa
normal working environment ona daily basis.
Items to Check./Ohanga
Chock Tank Safety Valve
Overall Unit Visual Check
Check Air Filter
DrainTank
Check Power Cord for Damage
Change Oil
Check Oil Level
Before each use
or daity
X
X
X
X
X
after first 50 hours
after every i00 hours
X
Storage
Forstoring the air compressor, be sure to do the following:
1. Turn the unit off and unplug the power cord from the
receptacle.
2. Remove all air hoses, accessories, and sir tools from
the air compressor.
3. Perform the daily maintenance schedule.
4 Open the drain valve to bleed all air from the tank.
5. Close thedrain valve.
6. Store the air compressor in aclean and dry location.
Notes