5925 Heisley Road • Mentor, OH
Series | |
Refrigerated Cabinets | |
Rev. 3 (10/06) | Page 3 of 4 |
|
|
OPERATING and MAINTENANCE INSTRUCTIONS
for Cres Cor Refrigerated Cabinets,
Model
MAINTENANCE:
HOW TO CHARGE AND SERVICE THE REFRIGERATION SYSTEM
Note: The refrigerator is shipped fully charged.
The
low pressure should be approximately 18 PSI at 75° F (24° C) room temperature. The charge should be 18 ounces of R134a.
Service valves are located on the condenser/compressor assembly.
Unit Condition:
Unit is plugged in. Switch is ON.
Failure | Probable Cause | ||
1. | Power light off | 1. | Power Cord |
2. | Compressor off | 2. | Power supply down |
3. | Evaporator fan on, Power | 3a. Thermostat defective | |
| light on and Compressor off | 3b. Defective start relay (compressor) | |
4. | Compressor on and cabinet | 4a. Low charge | |
| not cooling | 4b. Frost | |
|
| 4c. Evaporator fan defective | |
|
| 4d. Thermostat defective |
5.Compressor starts and stops; cabinet not cooling
6.Noisy compressor
NOTES:
5a. Low Charge
5b. Faulty start capacitor (compressor)
5c. Faulty start relay (compressor)
6a. Low charge
6b. Defective
1.Thermostat is
2For replacement of the electrical parts, refer to our list of authorized service centers