Digital Audio Processor with Room Control Crestron C2N-DAP8RC

60 Digital Audio Processor with Room Control: C2N-DAP8RC Operations Guide - DOC. 8187A
NOTE: If problems arise when transferring any Cresnet file (touchpanel
project/firmware), lower the port speed baud rate to 38400 to match the Cresnet bus
speed.
“Open” Window
4. Browse to the .upg file and click Open to begin the transfer.
Future upgrades may include upgrades to the DSP. In that event, the upgrade will
consist of an upgrade file (xxx.upg) plus one or more DSP files. The uploading
process would be the same, except that it will be important to load the accompanying
.upg file first, and then upload the DSP files.

Problem Solving

Troubleshooting

The following table provides corrective action for possible trouble situations. If
further assistance is required, please contact a Crestron customer service
representative.
C2N-DAP8RC Troubleshooting
TROUBLE POSSIBLE
CAUSE(S) CORRECTIVE ACTION
C2N-DAP8RC
does not
function.
Incorrect power
supply.
Use a Crestron power supply with sufficient
power for the network.
PWR LED
does not
illuminate.
C2N-DAP8RC is
not receiving
power.
Verify that cable plugged into NET port is
secure.
(continued on next page)