Crestron C2N-DAP8RC Digital Audio Processor with Room Control

Operations Guide – DOC. 8187A Digital Audio Processor with Room Control: C2N-DAP8RC 57
“Port Settings” Window
NOTE: The parameters shown in the illustration above are the port settings for a
PRO2 control system. Consult the Operations Guide for the control system being
used for exact parameter selection.
4. To verify communication, select Diagnostics | Establish
Communications (Find Rack). This should display a window that
gives the COM port and baud rate. If communication cannot be
established, refer to the “Troubleshooting Communications” section in
the respective Operations Guide for the control system.

Uploading a SIMPL Windows Program

A control system source file has
the extension .smw. A compiled
SIMPL Windows file has the
extension .spz for a 2-Series
control system.
The SIMPL Windows file can be uploaded to the control system using SIMPL
Windows or via the Crestron Viewport.

Upload via SIMPL Windows

1. Start SIMPL Windows.
2. Select File | Open to view the “Open” window, navigate to the SIMPL
Window file (.smw), and click Open.
3. Select Project | Transfer Program.

Upload via Crestron Viewport

1. Verify that the procedure for “Communication Settings” that begins on
page 55 has been performed.
2. As shown after this step, select File Transfer | Send Program
(alternatively, press Alt+P) from the Viewport menu.