Crestron CEN-UPS1250 Uninterruptible Power Supply

RoomView® and Control System Integration

Monitoring and operation of the CEN-UPS1250 extends beyond its front panel,
providing direct communication with Crestron’s RoomView Remote Asset
Management Software as well as with Ethernet enabled 2-Series control systems.
The CEN-UPS1250 notifies RoomView whenever it switches to battery backup and
warns if the battery is low or overloaded. It also reports which outlet banks are on, as
well as the line voltage, output voltage, frequency, voltage regulation status, system
load, internal temperature, ambient temperature and humidity and battery condition.
Centralized monitoring and logging via RoomView provides an invaluable resource
for quickly resolving power line problems and maintaining batteries.

Built-in Logging

In addition to RoomView, the CEN-UPS1250 also supports onboard timestamp
logging. Data can be set to log every 1 to 60 minutes with sufficient memory for at
least 30 days of history, recording the load, battery condition, line voltage, outlet
on/off status and environmental conditions. Instantaneous events such as switching
to battery, low battery warnings and self tests are also logged.

Rack Mountable

A heavy duty rack mount hardware kit is provided to mount the unit into any EIA
standard four post 19” equipment rack up to 28” deep. The feet on the bottom of the
unit can be unscrewed and removed to save space when the unit is rack-mounted.
Specifications
Specifications for the CEN-UPS1250 are listed in the following table.
CEN-UPS1250 Specifications
SPECIFICATION DETAILS
UPS/Power Conditioner
Output Power Capacity 1250 Watts (1440 VA) @ 120 Volts AC
nominal
Efficiency 90% at full load
Output Voltage Distortion <5% at full load
Output Frequency 47 to 63 Hz (sync to line power input)
Waveform Type Sine wave
Transfer Time 7 ms typical, 10 ms maximum during
blackout
Power Line Surge Protection Rated for 4080 Joules
Filtering Full time multi-pole noise filtering, 5% IEEE
surge let-thru, zero clamping response
time, meets UL 1449 Dataline protection
Voltage Regulation Performs voltage boost or trim to maintain
120 V nominal output
Maximum Output Current 12 Amps per outlet, 12 Amps total
Power Requirements
Input Voltage 92 to 142 Volts AC, 120 Volts nominal
Input Frequency 47 to 63 Hz
Maximum Input Current 12 Amps (when fed from 15 Amp circuit)
(Continued on following page)