Residential Lighting Design Guide |
|
| Occupancy and Photocell Sensors | |||||
Occupancy and Photocell Sensors | ||||||||
|
|
|
|
|
|
|
| |
|
| Green Light Occupancy Sensors | ||||||
|
| Crestron Green Light™ sensors deliver a powerful and | ||||||
|
|
| ||||||
|
| enhancing the functionality of lighting and environmental | ||||||
|
| systems. Crestron offers ceiling and wall mount occupancy | ||||||
|
| sensors for areas up to 2500 square feet. | ||||||
|
| Advanced | ||||||
|
| of ultrasonic and passive infrared technologies affords | ||||||
|
| extreme reliability for control of lighting, climate control and | ||||||
|
| other devices in the room. A | ||||||
|
| override the occupancy sensor if the ambient light level is | ||||||
|
| above a set threshold, preventing lights from turning on when | ||||||
|
| there is sufficient daylight in the room. | ||||||
|
| Sensors are easily connected to the lighting control processor | ||||||
|
| via the Cresnet control network using a | ||||||
|
| Integration Module. Alternately, they may be connected | ||||||
|
| directly via a digital input port. Please refer to the product | ||||||
|
| specification sheet for complete information. | ||||||
|
|
|
|
|
|
|
|
|
| Model | Mount Type |
| Coverage Area | Coverage Pattern |
| ||
|
|
|
|
|
|
|
|
|
| Ceiling |
| 500 sq ft | 180 degrees |
| |||
| Ceiling |
| 1000 sq ft | 360 degrees |
| |||
| Ceiling |
| 2000 sq ft | 360 degrees |
| |||
| Wall |
| 1200 sq ft | 110 degrees |
| |||
| Ceiling |
| 450 sq ft | 360 degrees |
| |||
| Ceiling |
| 1500 sq ft | 360 degrees |
| |||
| Wall |
| 2500 sq ft | 110 degrees |
| |||
|
|
|
|
|
|
|
| |
|
| Green Light Photocell Light Sensors | ||||||
|
| Crestron Photocell Light Sensors are designed for daylight | ||||||
|
| harvesting applications to control the balance of natural and | ||||||
|
| artificial lighting in an indoor space. By harnessing natural | ||||||
|
| daylight from windows and skylights, electrical lighting can | ||||||
|
| be turned off or dimmed, reducing energy usage while | ||||||
|
| maintaining a consistent light level for a more efficient and | ||||||
|
| comfortable work space. Outdoor lighting may also be turn | ||||||
|
| off and on automatically using a photocell light sensor. | ||||||
|
| Please refer to the product specification sheet for complete | ||||||
|
| information. |
|
|
| |||
|
|
|
|
|
| |||
| Model | Field of View |
| Light Sensitivity |
| |||
|
|
|
|
|
| |||
| 60 degree cone |
| 0 to 70 foot candles |
| ||||
|
| 60 degree cone |
| 3 to 6000 foot candles |
|
Doc. 5999F | 58 |