4-wire connection : Direct wire

Important : Grounding through the neutral conductor is prohibited for (1) new branch-circuit installations, (2) mobile homes, (3) recreational vehicles, and (4) areas where local codes prohibit grounding through the neutral conductor. Prepare minimum 5 ft (1.52 m) of length in order for dryer to be replaced. First, peel 5 inches (12.7 cm) of covering material from end. Strip 5 inches of ground wire insulation. After cutting 11/2 inch (3.8 cm) from 3 other wires peel insulation back 1 inch (2.5 cm). Make ends of 3 wires a hook shape.

Then, put the hooked shape end of the wire under the screw of the terminal block (hooked end facing to the right) and pinch the hook together and screw tightly.

1.Connect neutral wire (white) of power cord to center terminal block screw.

2.Connect red and black wires to the left and right terminal block screws.

3.Connect ground wire (green) of power cord to external ground screw and move neutral ground wire of appliance and connect it to center screw.

4.Make sure that the strain relief screw is tightened.

Be sure that all terminal block nuts are on tight and power cord is in right position.

16

Page 16
Image 16
Crosley CDE-8000GS, CDE-8000GW, CDE-8000GR, CDE-8000GBL manual Wire connection Direct wire