Power
Voltage Conversion
| PB/CSL Universal Fuse Board |
| |
|
| P16 | P6 |
| P10 |
|
|
|
| P15 | P5 |
| P9 | P14 | P4 |
|
|
| |
| P8 |
|
|
|
| P13 | P3 |
| P7 | P12 | P2 |
|
| ||
BLU | P19 |
|
|
| P20 | P11 | P1 |
BRN |
|
| |
|
|
| P22 |
| F100 | F1 | P21 |
| P18 | P17 |
|
S1 Power Switch
Note: The only versions of this product produced at the Crown Factory with international volt- age capabilities built in are CSL versions built specifically for sale outside the United States.
100V Connections:
P10 to P15
P11 to P14
P7 to P12
120V Connections:
P10 to P16
P11 to P14
P7 to P13
220V Connections:
P10 to P15
P9 to P14
P8 to P13
240V Connections:
P10 to P16
P9 to P14
P8 to P13
For list of applicable transformer, fuse F100, fanformer, and power cord refer to voltage- parts
Specific parts are required for the
100V AC Mains: |
|
10A Fuse | |
0.5A Low Voltage Supply Fuse | |
Power Transformer (Universal) | D |
Transmotor 120V 50 Hz | |
120V AC Mains: |
|
10A Fuse | |
0.5A Low Voltage Supply Fuse | |
Power Transformer (Universal) | D |
Power Transformer (United States) | D |
Transmotor 120V 50 Hz | |
Transmotor 120V 60 Hz | |
220V to 240V AC Mains: |
|
5A Fuse | |
0.5A Low Voltage Supply Fuse | |
Power Transformer | D |
Transmotor 120V 50 Hz |
7