`` SPECIFICATIONS

Performance

Sensitivity (for full rated power at 4 ohms): 1.25 Vrms.

Frequency Response

(at 1 watt, 22 Hz to 20 kHz): +0 dB, –1 dB.

Signal-to-Noise Ratio

(20 Hz to 20 kHz, inputs terminated): A-weighted, below rated power: > 100 dB. No weighting, below rated power: > 95 dB.

Total Harmonic Distortion (THD): < 0.5%.

Intermodulation Distortion (IMD):

(60 Hz and 7 kHz at 4:1) from full rated output to –40 dB: < 0.3%.

Damping Factor (8 ohm) 10 Hz to 400 Hz: >200.

Crosstalk (below rated power): at 1 kHz: –75 dB.

at 20 kHz: –59 dB.

Input Impedance (nominal):

20 kilohms balanced, 10 kilohms unbalanced.

Load Impedance: 2 to 8 ohms per channel in Stereo, 4 to 8 ohms in Bridge Mono.

AC Line Voltage and Frequency Configurations Available (±10%): 120 VAC 60 Hz, 100 VAC 50/60 Hz, 220 VAC 50 Hz,

and 230-240 VAC.

Controls

Level: Two front-panel rotary level controls, one for each channel.

Power: Front-panel switch; on when in the IN position.

Circuit Breaker: Back-panel breaker provides overload protection.

Mode Switch: Back-panel switch selects Dual or Bridge-Mono mode.

Indicators

Signal Presence Indicators: Two green LEDs, one for each channel, illuminate when the channel’s input signal exceeds –40 dBu.

Clip Indicators: Two red LEDs, one for each channel, illuminate when the channel’s output is being overdriven.

Power Indicator: Blue LED indicates amplifier has been turned on and AC power is available.

Fault Indicator: Two red LEDs, one for each channel, illuminate when amplifier is in protect mode. Also illuminates briefly during normal power-up when amplifier is first switched on.

Input/Output

Input Connectors: One per channel; back-panelthree-pin female XLR input connectors.

Output Connectors: Two 4-Pole Speakon® Output Connectors accept 2-pole or 4-pole Speakon® connectors. The top Speakon connector is wired for both channels so it can be used for bridge-mono wiring or for stereo wiring of two speakers to a single Speakon connector.

One pair of back-panel binding posts per channel; accepts banana plugs or bare wire. (European models do not accept banana plugs.)

Protection

Provides extensive protection and diagnostic capabilities, including output current limiting, DC protection, circuit breaker, and thermal protection.

Construction

Ventilation: Flow-through ventilation from front to back.

Cooling: Internal heat sinks with forced-air cooling for rapid, uniform heat dissipation.

Air Volume Requirements

(per minute per unit): 80.15 ft³ (2.27 m³).

Dimensions: EIA Standard 19-inch (48.3-cm) rack mount width (EIA RS-310-B), 5.25-inch (13.3-cm) height and 15.5-inch (39.5-cm) depth.

Weight

Net Weight: 62.0 lb (27.7 kg)

Shipping Weight: 74.0 lb (33.6 kg)

Regulatory Certifications

Other Applications

3/08

139436-3B

P O R TA B L E P A

The XLS 5000 power amplifier from Crown represents a new era in affordable, quality power amplification. It incorporates the best of tried-and-true design principles and innovative

features, all in a rugged, light-weight 3U chassis.

Page 37
Image 37
Crown CTS 2000, CTS 3000, CTS 1200, CTS 600 manual Shipping Weight 74.0 lb 33.6 kg

CTS 600, CTS 1200, CTS 2000, CTS 3000 specifications

Crown, a leading name in material handling equipment, has developed the Crown CTS series, which includes the CTS 3000, CTS 2000, CTS 600, and CTS 1200 models. Each of these rugged machines is designed to enhance productivity and efficiency in various warehouse and distribution applications, integrating innovative technologies and robust features.

The Crown CTS 3000 is the flagship model in this series, designed for high-demand environments that require exceptional lifting capability. It boasts a powerful AC drive system that offers superior acceleration and speed control, providing operators with smooth and responsive handling. The heightened visibility from the operator's compartment minimizes blind spots, enhancing safety and efficiency during operations. The CTS 3000 also features advanced battery management technology, allowing for prolonged operation and minimal downtime.

Next in line is the Crown CTS 2000, which is tailored for a range of medium-duty applications. While its lifting capacity is slightly lower than the CTS 3000, it incorporates many similar functionalities. It features a user-friendly control interface, making it easy for operators of any skill level to manage tasks efficiently. The robust design ensures reliability and durability, making it an excellent choice for businesses that require consistent performance under moderately demanding conditions.

The Crown CTS 600 model is specially designed for light-duty operations. Ideal for shorter runs and smaller spaces, the CTS 600 is compact and maneuverable without compromising on performance. It comes equipped with advanced safety features, including an integrated operator presence system that ensures safe operation. The model’s light weight also translates into better battery efficiency, making it a cost-effective option for businesses seeking to optimize their operational expenses.

Lastly, the Crown CTS 1200 is a versatile model that strikes a balance between power and agility. It is particularly suitable for environments where space is at a premium. The CTS 1200 is engineered for versatility, allowing it to handle a variety of loads with ease. It features intuitive controls and exceptional ergonomics, contributing to operator comfort during long shifts. This model also emphasizes energy efficiency and reduced environmental impact through its advanced power management system.

In summary, the Crown CTS series offers a range of models catering to varying operational needs, from high-demand environments with the CTS 3000 to the space-saving capabilities of the CTS 600. Each model is built upon a foundation of advanced technologies that promote safety, efficiency, and productivity, making them indispensable tools in today's material handling landscape.