![`` SPECIFICATIONS](/images/new-backgrounds/25527/255279x1.webp)
`` SPECIFICATIONS
Frequency Response (at 1 watt, 20 Hz - 20
kHz): ±0.25 dB.
Signal to Noise Ratio below rated power (20 Hz to 20 kHz): 105 dB
Total Harmonic Distortion (THD) at full rated power, from 20 Hz to 20 kHz: CTs 600/1200:
<0.1%. CTs 2000/3000 < 0.35%. Damping Factor: 10 Hz to 100 Hz: > 3000.
Crosstalk (below rated power, 20 Hz to 1 kHz): > 80 dB.
Common Mode Rejection (CMR) (20 Hz to 1 kHz): 50 dB.
DC Output Offset: < ±2 mV.
Input Impedance (nominal): 10 kilohms bal- anced, 5 kilohms unbalanced.
Maximum Input Level: +20 dBu before input compression, +32 dBu absolute maximum.
Load Impedance: (Note: Safe with all types of loads)
CTs 600/1200
Stereo: 2/4/8/16 ohms, 70V, 100V
Bridge Mono: 4/8/16 ohms, 140V.
CTs 2000/3000
Stereo: 2/4/8/16 ohms, 70V, 100V
Bridge Mono: 4/8/16 ohms, 140V, 200V.
Voltage Gain (at maximum level setting):
8/4 ohm operation, 1.4V sensitivity CTs 600 35:1 (31 dB)
CTs 1200 50:1 (34 dB)
CTs 2000 63.9:1 (36 dB)
CTs 3000 71.4:1 (37 dB).
26 dB: 20:1 (26 dB).
70V operation, 1.4V sensitivity or 100V operation, 2.0V sensitivity: 50:1 (34 dB).
AC Line Voltage and Frequency Configurations Available (±10%): 120VAC/60Hz, 230VAC/50 Hz.
Power Draw at Idle (120VAC mains):
CTs 600/1200: 24W (standby mode)
CTs 2000/3000: 35W (standby mode).
Cooling: Continuously variable speed forced air,
Dimensions: 19 in. (48.3 cm) W x 3.5 in. (8.9 cm) H x 14.25 in. (36.2 cm) D.
Weight: Net, Shipping
CTs 600: 22.8 lb (10.3 kg), 27.7 lb (12.6 kg)
CTs 1200: 23.4 lb (10.6 kg), 28.3 lb (12.8 kg)
CTs 2000: 27.0 lb (12.2 kg), 32.0 lb (14.5 kg)
CTs 3000: 27.7 lb (12.6 kg), 32.7 lb (14.8 kg).
Front Panel Controls and Indicators
Bridge Mode Indicator: Yellow LED illuminates when the
Ready Indicator: Green LED, one per channel, illuminates when the channel is initialized and ready to produce audio output. Indicator is off when PIP puts the amplifier in standby mode via the control system.
Signal Indicators: Three green LEDs per chan- nel indicate the amplifier’s input and output signal levels.
Signal: input signal is above
Clip Indicator: Red LED, one per channel, illuminates when the channel’s output signal reaches the onset of audible clipping. The Clip Indicator also will illuminate during Thermal Level Control (TLC) limiting or when the input compressor/limiter is protecting the amplifier from input overload.
Thermal Indicator: Red LED, one per channel, illuminates when the channel has shut down, or is very near shutting down, due to thermal stress or overload.
Fault Indicator: Red LED, one per channel, flashes when the amplifier output channel has stopped operating.
Data Indicator: Yellow LED indicates control data activity (if the amplifier is equipped with an
Power Indicator: Blue LED indicates amplifier has been turned on and AC power is available. The LED will flash when the AC line voltage is 15% above or 25% below the nominal rated value.
Cooling Vents:
Power Switch:
Back Panel Controls and Connectors
Power Cord Connector: Standard 15 amp IEC inlet. Voltage is indicated above IEC inlet.
Reset Switch: Resets the circuit breaker that protects the power supply.
Speaker Connectors: One
Input Connectors: Balanced
Channel Level Control: One
Mode Switch:
select the amplifier’s mode of operation: Dual or
Highpass Filter: One
“Y” Input Switch: When set to ON, this switch parallels the input signals of the two channels for use when the input signal is mono. Also can be used to
Ventilation Grille:
Options
PIP2 modules, including the
Protection Systems
Thermal Level Control (TLC): If an amplifier channel starts to overheat, the TLC circuit will engage the input compressor. By compressing the input, the amplifier will not generate as much heat and will have a chance to cool down.
Junction Temperature Simulation (JTS): In the CTs 600/1200, if excess power is demanded, JTS circuitry limits the drive level of the output devices to a safe range, preventing damage.
Fault: The amplifier will light the Fault LED if the amplifier output stage stops operating.
AC
Circuit Breaker: This breaker protects the ampli- fier from excessive AC current draw.
DC Output Servo: The output servo circuit protects your drivers by eliminating DC offset, even in the presence of very large asymmetrical signals.
Regulatory Certifications
Other Applications
9/07 |
INSTALLED SOUND
Crown’s CTs Series amplifiers provide exceptional performance, flexibility and value for installed sound applications. CTs Series amplifiers feature independent selection of high and low impedance operation for a specific channel, plus power levels and features that were carefully chosen to match the requirements of fixed install design. Easy integration with HiQnet™ and CobraNet™ allows CTs amplifiers to deliver a comprehensive lineup of monitoring and control features along with digital audio
transport for an