Crown Audio ce 4000 Operation, CE 4000 Power Amplifier, page, 2 Back Panel Controls and Connectors

Models: ce 4000

1 24
Download 24 pages 60.45 Kb
Page 12
Image 12
4.3Back Panel Controls and Connectors

CE 4000 Power Amplifier

4 Operation

4.3Back Panel Controls and Connectors

H.Balanced Barrier Block Inputs (if equipped)

Screw-terminal Barrier Block. One set per channel.

I.Neutrik® Combo Balanced Inputs Combination three-pin female XLR and TRS. One per channel.

J.Neutrik® Speakon® Outputs (if equipped)

Accept male NL4C connector.

K.5-Way Binding Post Outputs (if equipped)

Accept banana plugs, spade lugs or bare wire. (European models do not accept banana plugs). One pair per channel

L.IEC Power Connector

M.Fault Connector

Female RJ-45 for connection to external circuit to monitor amplifi er Fault status.

N.Sensitivity Switch

Allows selection of .775V, 1.4V or 26-dB sensitivity.

O.Mode Switch

Allows selection of Stereo or Bridge operation.

P.Low-Pass Filter Switch

Allows selection of Flat, 80 Hz or 100 Hz roll-off. One per channel.

Q.High-Pass Filter Switch

Allows selection of Flat, 30 Hz, 40 Hz or 50 Hz roll-off. One per channel.

R.3-Speed Fan-on-Demand

Provides forced-air cooling of the amplifi er.

Figure 4.2 Back Panel Controls and Connectors