5 Troubleshooting

CONDITION: No sound, even though the amp has power. Power LED is on with-

out flashing and the amp is receiving an input sig- nal. Signal indicator is on or flashing.

POSSIBLE REASON:

• Speakers not connected.

• Open circuit due to speaker failure.

• There is a short on the amplifier output. First disconnect your speakers from the affected channel(s) one by one to determine if one of the loads is shorted.

• Ready LED is off. Channel has been set to standby mode via the software.

CONDITION: No input signal. Signal indicator is not flashing even though audio is applied, and the channel is ready.

POSSIBLE REASON:

• Input signal level is very low.

CONDITION: Data indicator not flash- ing, even though host computer IQ software is active.

POSSIBLE REASON:

Cable between computer and amplifier is bro- ken or not connected.

Note: Data indicator flashes only when the amplifier is polled for data, or is polled to see whether it is online.

CONDITION: Yellow LINK ACTIVITY indicator in Ethernet connector does not illuminate or flash.

POSSIBLE REASON:

Ethernet link is broken.

CONDITION: Yellow LINK ACT indicator is on but green 100Mb indicator in Ethernet connector does not illuminate.

POSSIBLE REASON:

Network connection is 10Mb. The I-Tech can work on a 10Mb connection but 100Mb is optimum.

CONDITION: Computer does not communicate with the network devices.

POSSIBLE REASON:

Incorrect wiring. See Section 4.5.4 on wiring.

IP Addressing is not done correctly. See Section 4.5.5 on address- ing rules.