4 Advanced Operation

Clip Errors: This screen lets you view clip errors without using IQwic or System Archi- tect. A clip error occurs if the number of clip events exceeds the value set with the Count slider (within the time set by the Time slider) on the Error Reporting Page of the IQwic Control Panel or Amplifier Settings in System Architect.

When an error occurs, the count displayed in this screen is incremented, and the operat- ing time since the error is displayed.

To clear this screen, press and release an Encoder. The display will prompt you to confirm your choice by pressing and holding the Encoder.

NOTE: You must use IQwic or System Architect to enable error reporting and set its limits.

Clip Errors

114 111

118.4 Hrs Last 118.4 Hrs

Thermal Errors: This screen lets you view thermal errors without using IQwic or Sys- tem Architect. A thermal error occurs if the amplifier thermal % exceeded the value set with the Thermal slider on the Error Reporting Page of the IQwic Control Panel or Amplifier Settings in System Architect.

When an error occurs, the count displayed in this screen is incremented, and the operat- ing time since the error is displayed.

To clear this screen, press and release an Encoder. The display will prompt you to confirm your choice by pressing and holding the Encoder.

NOTE: You must use IQwic or System Architect to enable error reporting and set its limits.

Thermal Errors

4

0

148.3 Hrs Last

None

Low Limit Load Errors: This screen lets you view low-load errors without using IQwic or System Architect. A low limit load error occurs if the load impedance falls below the value set with the Low Limit spin control on the Load Monitoring Page of the IQwic Control Panel or Amplifier Settings in System Architect.

When an error occurs, the count displayed in this screen is incremented, and the operating time since the error is displayed.

To clear this screen, press and release an Encoder. The display will prompt you to confirm your choice by pressing and holding the Encoder.

NOTE: You must use IQwic or System Architect to enable error reporting and set its limits.

Low Limit Load Errors

44 32

120.1 Hrs Last 120.1 Hrs

Operation Manual

High Limit Load Errors: This screen lets you view high limit load errors without using the control software. A high limit load error occurs if the load impedance rises above the value set with the High Limit value on the software Control Panel.

When an error occurs, the count displayed in this screen is incre- mented, and the operating time since the error is displayed.

To clear this screen, press and release an Encoder. The display will prompt you to confirm your choice by pressing and holding the Encoder.

NOTE: You must use IQwic or System Architect to enable error report- ing and set its limits.

High Limit Load Errors

10

56.1Hrs Last None

Line Voltage Errors: This screen lets you view line-voltage errors without using control software. A line voltage error occurs if the line voltage falls outside the values set with the High/Low Limits slider on the Line Voltage Page of the Control Panel.

When an error occurs, the count displayed in this screen is incre- mented, and the operating time since the error is displayed. The “Low” and “High” indicators show whether the line voltage was below or above the line-voltage limits.

To clear this screen, press and release an Encoder. The display will prompt you to confirm your choice by pressing and holding the Encoder.

NOTE: You must use IQwic or System Architect to enable error report- ing and set its limits.

Line Voltage Errors

14Low

High 2

6.8 Hrs

Last 70.3 Hrs

Exit: To exit the Monitor Menu and go to the Attenuation screen, press Menu/Exit once.

page 21

Page 21
Image 21
Crown Audio I-Tech Series operation manual Advanced Operation, I-TechSeries Power Amplifiers, page, 14Low, High