4 Advanced Operation
Clip Errors: This screen lets you view clip errors without using IQwic or System Archi- tect. A clip error occurs if the number of clip events exceeds the value set with the Count slider (within the time set by the Time slider) on the Error Reporting Page of the IQwic Control Panel or Amplifier Settings in System Architect.
When an error occurs, the count displayed in this screen is incremented, and the operat- ing time since the error is displayed.
To clear this screen, press and release an Encoder. The display will prompt you to confirm your choice by pressing and holding the Encoder.
NOTE: You must use IQwic or System Architect to enable error reporting and set its limits.
Clip Errors
114 111
118.4 Hrs Last 118.4 Hrs
Thermal Errors: This screen lets you view thermal errors without using IQwic or Sys- tem Architect. A thermal error occurs if the amplifier thermal % exceeded the value set with the Thermal slider on the Error Reporting Page of the IQwic Control Panel or Amplifier Settings in System Architect.
When an error occurs, the count displayed in this screen is incremented, and the operat- ing time since the error is displayed.
To clear this screen, press and release an Encoder. The display will prompt you to confirm your choice by pressing and holding the Encoder.
NOTE: You must use IQwic or System Architect to enable error reporting and set its limits.
Thermal Errors
4 | 0 |
148.3 Hrs Last | None |
Low Limit Load Errors: This screen lets you view
When an error occurs, the count displayed in this screen is incremented, and the operating time since the error is displayed.
To clear this screen, press and release an Encoder. The display will prompt you to confirm your choice by pressing and holding the Encoder.
NOTE: You must use IQwic or System Architect to enable error reporting and set its limits.
Low Limit Load Errors
44 32
120.1 Hrs Last 120.1 Hrs
Operation Manual
High Limit Load Errors: This screen lets you view high limit load errors without using the control software. A high limit load error occurs if the load impedance rises above the value set with the High Limit value on the software Control Panel.
When an error occurs, the count displayed in this screen is incre- mented, and the operating time since the error is displayed.
To clear this screen, press and release an Encoder. The display will prompt you to confirm your choice by pressing and holding the Encoder.
NOTE: You must use IQwic or System Architect to enable error report- ing and set its limits.
High Limit Load Errors
10
56.1Hrs Last None
Line Voltage Errors: This screen lets you view
When an error occurs, the count displayed in this screen is incre- mented, and the operating time since the error is displayed. The “Low” and “High” indicators show whether the line voltage was below or above the
To clear this screen, press and release an Encoder. The display will prompt you to confirm your choice by pressing and holding the Encoder.
NOTE: You must use IQwic or System Architect to enable error report- ing and set its limits.
Line Voltage Errors
14Low | High 2 |
6.8 Hrs | Last 70.3 Hrs |
Exit: To exit the Monitor Menu and go to the Attenuation screen, press Menu/Exit once.