Fig. 3
60˚ | 90˚ | 120˚ | |
|
|
| 1 kHz |
|
|
| 200 Hz |
|
|
| 5 kHz |
30˚ |
|
| 150˚ |
FRONT |
|
| REAR |
0˚ | 180˚ | ||
+5 |
|
Fig.4a
.974"
.153".300"
.379"
.618"
1.981"
.680 DIA.
1.094 DIA.
1.300 DIA.
Fig.4b
1.496" DIA.
(3.8 CM)
.062"
(.2 CM)
1.010"
(2.6 CM)
2.200"
(5.6 CM)
1.130"
(2.9 CM)
1.025" DIA.
(2.6 CM)
1.250" DIA.
(3.2 CM)
Fig.5
BOTTOM VIEW |
|
PHONE PLUG | SCREWDRIVER |
| |
FRONT | LIFT WASHER AND |
| PRY OPEN HERE AND |
| ON OPPOSITE SIDE |
AFTER REASSEMBLY |
|
RESEAT WASHER |
|
Installation
1.If the microphone will be used on a lectern, install it on an open surface. Do not install in a cavity or recessed area as the frequency re- sponse and polar pattern will be degraded.
2.Drill a hole
3.When you install the insert, make sure that the locating pin for the microphone is facing in the desired direction. Orient the mic so the word “Crown” is readable by the user (right-
4.Wire the mic to the
5.Plug each mic into its jack. The front of the mic is indicated by the Crown logo on the mi- crophone.
6.After use, you may remove the mics and cover their inserts with the supplied disks.
Architects’ and Engineers’ Specifications
The microphone shall be the Crown model
The microphone shall exhibit excellent
A table insert with phone jack shall be included. The mic shall be used with a pluggable terminal block and an
The interface shall provide operating voltage to each microphone, and convert its output signal to
Nominal sensitivity shall be 22 mV/Pa. Maxi- mum SPL shall be 120 dB SPL for 3% THD. Equivalent noise shall be 22 dBA nominal. Fre- quency response shall be 50 Hz to 15 kHz with a uniform
The Crown models
Warranty
Crown professional microphone products are guaranteed against malfunction for a period of three years from date of original purchase. See enclosed warranty sheet for additional information.
Service
If the microphone does not function properly, check that it is aimed correctly and is con- figured and connected as described in the
If it is determined that the microphone needs additional service and you wish to return it to Crown, a Service Return Authorization (SRA) is required. An SRA can be completed online at www.crownaudio.com/support/factserv.htm. After securing an SRA, return the microphone in its original packaging to: Crown Factory
Service, 1718 W. Mishawaka Road, Elkhart, IN 46517-9439.
For further assistance or technical support call
Crown International, Inc. 1718 W. Mishawaka Rd. Elkhart, IN
©2008 Crown Audio®, Inc. Specifications subject to change without prior notice. Latest information available at www.crownaudio.com.
4/08 |