Contents
1111 North Hadley Road P.O. Box
Lincoln Foodservice Products, Inc
Technical Service Hot Line
Fort Wayne, Indiana Phone 800 374-3004 Fax
SEQUENCE OF OPERATION IMPINGER ADVANTAGE
SCHEMATIC DIAGRAM MODEL
SERIAL NUMBER N28654 AND ABOVE
TROUBLESHOOTING GUIDE
present, check for 24VAC at wire #20 output of
WITH POWER OFF Turn motor to check for locked
Centrifugal switch of burner
off valve is located between valve assembly and
temperature reading, but the oven will not heat
adjustment. With the control set at maximum
temperature, check for 120VAC at the temperature
WITH POWER ON AND THERMOCOUPLE
Switch, conveyor reversing
WITH POWER OFF Check the motor windings as
before testing
motor, capacitor, and reversing switch check good
FAN SPIDER FAN HUB CONE
REMOVAL, INSTALLATION & ADJUSTMENTS
IMPINGER ADVANTAGE SERIES
NOTE MEASUREMENT MUST BE
3.Remove lead wires and mark for reassembly
THERMOSTAT, COOLING FAN - REPLACEMENT
1.Shut off power at main breaker
BURNER BLOWER MOTOR - REPLACEMENT
6.Remove incoming nipple
3.Remove burner assembly. SEE BURNER ASSY
BURNER IGNITOR - REPLACEMENT
1.Shut off power at main breaker
THERMOCOUPLE - REPLACEMENT
1.Shut off power at main breaker
1.Shut off power at oven switch
MAIN ORIFICE - REPLACEMENT
6.Remove assembly and replace main orifice
This page intentionally left blank
GENERAL VIEW ADVANTAGE SERIES
Page
CONTROL BOX
S/N N28654 and ABOVE
Page
OVEN BACK ADVANTAGE SERIES GAS AND ELECTRIC
Page
CONVEYOR 1450 SERIES
Page
Page