Cuisinart CGG-240 Checking for gas leak, Installing the gas cylinder, Lighting instructions

Models: CGG-240

1 9
Download 9 pages 54.17 Kb
Page 7
Image 7

5.Operating Your Grill (cont.)

5.2Special Instructions for the Use of Regulator and Propane Cylinder

5.4 Checking for gas leak

mDANGER

4.

Inspect the solution at the connections, looking for

 

bubbles. If no bubbles appear, the connection is secure.

5.

If bubbles appear, a leak is detected. Go to step 6.

A propane gas cylinder is required for operation. Use 1.00ibs(465g). propane cylinder.

This Cuisinart grill is equipped with a regulator having a CGA No.600 cylinder connection

1)Only cylinders marked “propane” must be used.

2)The cylinders be disconnected when the appliances is not in use

3)Do not store a spare LP-gas cylinder under or near this appliance;

4)Never fill the cylinder beyond 80 percent full; and

5)If the instructions in “-b12(a)” and “-b12(b)” are not followed exactly, a fire causing deathor serious injury may occur.

Propane cylinder size:D10cmXH20cm, Only cylinders marked “PROPANE” must be used.

The propane cylinder must be constructed and marked in accordance with the specification for LP-Gas cylinders of the U.S Department of Transportation (D.O.T) or the National standard of Canada, CAN/CSA-B339,Cylinders, spheres and Tubes for Transportation of Dangerous Goods.

Store spare fuel canisters in a well-ventilated area away from the grill.

Do not puncture or burn fuel canister.

If the grill is not in use, the control knob must be turned to the “OFF” position to shut off the gas flow from the cylinder.

REMOVAL OF THE GAS CYLINDER

(please see the 5.3 Installing the gas cylinder) “picture”

1)Turn the burner control knob to “OFF” position.

2)Grasp the grill handle nearest to the regulator with one hand, and turn the cylinder counterclockwise until it comes off.

Do not store a spare propane cylinder under or near this grill. Never fill the cylinder beyond 80 percent full. If this instruction is not followed exactly, a fire causing death or serious injury may occur.

Save the cylinder cap and reinstall when not in use.

Cylinder supply system must be arranged for vapor withdrawal. Do not block the pressure relief valve during use or storage.

The cylinder be disconnected when the appliance is not in use.

1)Do not store a spare LP-gas cylinder under or near this appliance;

2)Never fill the cylinder beyond 80 percent full; and

3)If the instructions in “-b12(a)” and “-b12(b)” are not followed exactly, a fire causing deathor serious injury may occur.

Check gas system for leaks to prevent fire or explosion hazard

1.The “Leak Check” must be performed before lighting the grill and each time the cylinder is connected for use.

2.Do not smoke or allow other sources of ignition in the area while conducting a leak test.

3.Conduct the leak test outdoors in a well-ventilated area.

4.Do not use matches, lighters or a flame to check for leaks.

5.Do not use grill until all leaks have been stopped, if you are unable to stop a leak, disconnect the propane supply, and call for gas application service or your local propane gas supplier.

Leak Check Method

1.Make 2-3 oz. of leak solution by mixing one part liquid dishwashing soap with three parts water.

2.Make sure control knob is in the “OFF” position.

3.Spray or paint some leak solution on the cylinder and regulator connection.

6.

Disconnect the cylinder from the regulator, and reconnect.

 

Make sure the connection is secure and no leak is found

 

before using the grill.

7.

If you continue to see bubbles, DO NOT USE THE

 

GRILL. Repeat the above process with a different LP

 

cylinder. If leaks are still present, contact the customer

 

service center.

 

 

 

 

5.3 Installing the gas cylinder

(The propane gas cylinder is not provided with the appliance.)

A gas cylinder complying with the requirements listed in section 4.2 must be obtained before the grill can operate. Connect the LP cylinder to the grill outdoors only.

Read and follow all direction on the cylinder.

1.Turn the burner control knob to “OFF” position.

2.Remove the protective caps from the cylinder valve and coupling nut, if present.

3.Open grill lid and remove right side table for easier ac- cess to regulator assembly.

4.Grasp the grill handle nearest to the regulator with one hand, and with the other hand push the cylinder into the threaded regulator connector and turn clockwise until tight.

5.TIGHTEN BY HAND ONLY. Do not use tools.

REMOVAL OF THE GAS CYLINDER

1.Turn the burner control knob to “OFF” position.

2.Grasp the grill handle nearest to the regulator with one hand, and turn the cylinder counterclockwise until it comes off.

5.5 Lighting instructions

1.Read all instructions before lighting.

2.Open lid during lighting.

3.Make sure the gas control knob is in “OFF” position.

4.Push the gas control knob and quickly turn counterclockwise to “HIGH” position. The igniter will click and light the burner.

5. If ignition does not occur in 5 seconds, turn the gas control knob off, wait 5 minutes, and repeat steps 2 - 5.

*Before cooking on this grill for the first time, operate the grill for about 15 minutes

with the lid closed and the gas turned on “HIGH”. This will “heat clean” the internal parts and dissipate odor from the painted finish.

*Clean your grill after each use. DO NOT use abrasive or flammable cleaners,

As it will damage the parts of this product and may start a fire. Clean with warm soapy water.

If the burner does not light, turn the gas control knob off and wait 5 minutes to let the gas clear before you try again. (please see the 5.3 Installing the gas cylinder)

12

13

Page 7
Image 7
Cuisinart CGG-240 Checking for gas leak, Installing the gas cylinder, Lighting instructions, Removal of the GAS Cylinder