INSTALLATION AND OPERATION MANUAL
MF3500G, MF3500S, MF3500B Models
OPERATING INSTRUCTIONS
UNDERSTANDING THE TRI-X CONTROLLER
The controller is located on the lower
ON KEY
Pressing the ON key will begin the startup sequence for the stove. Fuel will feed through the auger feed system after a brief exhaust check. This check assures the burn area is sealed and the flue gases are exiting the building. The draft fan (exhaust) will start as soon as the ON key is pressed. The fan will automatically adjust speed to match the heat requirement. The circulating blower will turn on when the stove heat level has reached 110°F. When this temperature is reached, the dial to the right of the
The LED light will illuminate when the ON key is pushed and remains on during normal operation.
OFF KEY
Pressing the OFF key will cause the stove to begin the
The LED will illuminate when the OFF key is pushed and remains on when the stove is not providing heat.
MODE KEY
The type of fuel is selected by pressing the MODE key. All the currently approved fuels can be viewed when scrolling (pressing) the MODE key.
There is no LED with this key.
TEMP UP OR TEMP DOWN KEYS
Pressing the TEMP UP or the TEMP DOWN keys will adjust the amount of fuel and air being delivered to the fire pot. There are six levels of heat from which to choose. Each level has been calibrated to deliver the correct ratio of air and fuel into the fire pot for the selected fuel type.
Controller Faceplate
L | H | 720038 |
|
Circulating Blower Dial Faceplate
Page 16 | CumberlandStoveWorks.com |