J2-1

J2-2

J2-3

100V max., 60mA max.

Wiring diagram 1.

 

2.4 Environmental

 

 

 

Operating temperature:

0°C to +50°C

 

Storage temperature:

-40°C to +85°C

 

Humidity:

95% non-condensing at 38°C

Shock:

SAEJ1378, 55g pulse at 9-13ms

Vibration:

5g rms, 5-500 Hz, 2 hrs. per axis

Protection:

IP-54, including fan

 

2.5 Compliance

 

 

 

Radiated Emissions:

FCC Part 15, Class A

EN55011, Class A

Conducted Emissions:

FCC Part 15, Class A

EN55011, Class A

EN50082-1-1997

 

X

ESD:

 

EN61000-4-2:1995

Radiated Immunity:

 

EN61000-4-3:1995 +

 

 

 

A1:1998

Electrical fast transient:

 

EN61000-4-4:1995

Surge Immunity:

 

EN61000-4-5:1995

Conducted Immunity:

 

EN61000-4-6:1996

Power Frequency Magnetic Field:

EN61000-4-8:1993

Voltage dips and sags:

 

EN61000-4-11:1995

Harmonics:

 

EN61000-3-2:2000

Voltage fluctuations (flicker)

 

EN61000-3-3:1995

Safety

 

EN60335-1:1995

 

 

 

EN60335-2-29:1997

2.6 Battery Types

This charger is suitable for use with all 24V, 12 cell, rechargeable lead acid batteries with capacities of approximately 200Ah.

2.7 Charge Cycle Profile

The Model 1620 charger provides three different charge profiles: IVa (Off Mode, see Figure 1), I1VI2a (Equalize Mode, see Figure 2) and IV1V2 (Float Mode, see Figure 3).

For definitions of the variables mentioned in this section, refer to Table 1.

Curtis 1620 Manual

page 2

Page 5
Image 5
Curtis 1620S manual Environmental, Compliance, Battery Types, Charge Cycle Profile