| 7 1/4" |
39 1/2" | (183mm) |
(1003mm) | 3" | |
FLUE VENT | ||
(76mm) | ||
6" (150mm) | ||
| ||
| 33 5/16" | |
| (848mm) |
BAKERS PRIDE
BAKERS
PRIDE
| 29" (737mm) | |
| 22" | |
14 13/32" | (559 mm) | |
6 9/32" | ||
(366 mm) | ||
(160mm) | ||
|
TOP VIEW
Doors open to 150°
20"
(508mm)3/4 NPT
GAS INLET
30"
(762mm)
FRONT VIEW
7 1/4"
(183mm)
3/4 NPT
GAS INLET
| 72 5/8" |
|
63 5/16" | (1.845mm) |
|
|
| |
(1608mm) |
|
|
| 44 5/8" |
|
| (1.133mm) |
|
| SIDE VIEW |
|
| Single Unit |
|
| 6" |
|
| 1(52mm) | SIDE VIEW |
|
| Double Unit |
ALL DIMENSIONS NOMINAL
335/16"
(848mm)
5315/16"
(1.370mm)
205/8"
(524mm)
SHIPPING INFORMATION
| Shipping Weight | Carton Size |
|
| Carton Dimensions |
|
| |||
Model | Lbs. | Kilos | Cubic Feet Cubic Meters |
| Width |
| Depth |
| Height | |
Inches | MM | Inches | MM | Inches | MM | |||||
|
|
|
|
|
| 660 | 349 | 43.5 | 1.23 | 43.5 | 1105 | 46.0 | 1168 | 37.5 | 952 |
| |||
|
| Shipped in two cartons as per above specifications |
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| POWER SUPPLY |
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| Model | BTUH |
| KW |
| HZ |
| Voltage 1O/ | Amps | Wire | Phase | ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 60,000 |
| 17.58 |
| 60 |
|
| 115 | 7.5 | 2 | 1 | 900 | 1,725 |
| |
| 60,000 |
| 17.58 |
| 60 |
| 208/240 | 4 | 2 | 1 | 1,140 | 1,725 |
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 60,000 |
| 17.58 |
| 50 |
|
| 230 | 4 | 2 | 1 | 950 | 1,425 |
| |
| 120,000 |
| 35.16 |
| 60 |
|
| 115 | 2 x 7.5 | 2 | 1 | 900 | 1,725 |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| 120,000 |
| 35.16 |
| 60 |
| 208/240 | 2 x 4 | 2 | 1 | 1,140 | 1,725 |
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 120,000 |
| 35.16 |
| 50 |
|
| 230 | 2 x 4 | 2 | 1 | 950 | 1,425 |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
GAS SUPPLY — 3/4" NPT rear connection
Gas Type | Manifold Pressure | Inlet Pressure | |||
WC | Mbar | Inches | Mbar | ||
| |||||
Natural | 3.5" | 9 min | 7" | 17.5 min | |
Propane |
|
| 11" | 27.5 min | |
| 10" | 25 max | 13" | 32.5 max | |
|
|
|
|
|
Separate gas connections or external manifold required for stacked ovens
MINIMUM CLEARANCES
| Vent Hood | Direct Venting |
| ||
| Inches | MM | Inches | MM |
|
Right | 1 | 25 | 1 | 25 |
|
Left | 1 | 25 | 3 | 76 |
|
Rear | 3 | 76 | 3 | 76 |
|
Suitable for installation on combustible floors when installed on factory supplied legs or casters
| BAKERS PRIDE OVEN COMPANY, INC. | Continuous product improvement is a policy of Bakers Pride Oven Company. | |
| Therefore, specifications and design are subject to change without notification | ||
BAKERS | 30 Pine Street, New Rochelle, NY 10801 | ||
TS: 3M 11/04 | |||
PRIDE |
| ||
|
| ||
|
|
|