CyClone CO11-G1 TOP VIEW Doors open to, Front View, Side View, Single Unit, Gas Inlet, 44 5/8

Models: CO11-G1

1 2
Download 2 pages 62.92 Kb
Page 2
Image 2
TOP VIEW

 

7 1/4"

39 1/2"

(183mm)

(1003mm)

3"

FLUE VENT

(76mm)

6" (150mm)

 

 

33 5/16"

 

(848mm)

BAKERS PRIDE

BAKERS

PRIDE

 

29" (737mm)

 

22"

14 13/32"

(559 mm)

6 9/32"

(366 mm)

(160mm)

 

TOP VIEW

Doors open to 150°

20"

(508mm)3/4 NPT

GAS INLET

30"

(762mm)

FRONT VIEW

7 1/4"

(183mm)

3/4 NPT

GAS INLET

 

72 5/8"

 

63 5/16"

(1.845mm)

 

 

 

(1608mm)

 

 

 

44 5/8"

 

 

(1.133mm)

 

 

SIDE VIEW

 

 

Single Unit

 

 

6"

 

 

1(52mm)

SIDE VIEW

 

 

Double Unit

ALL DIMENSIONS NOMINAL

335/16"

(848mm)

5315/16"

(1.370mm)

205/8"

(524mm)

SHIPPING INFORMATION

 

Shipping Weight

Carton Size

 

 

Carton Dimensions

 

 

Model

Lbs.

Kilos

Cubic Feet Cubic Meters

 

Width

 

Depth

 

Height

Inches

MM

Inches

MM

Inches

MM

 

 

 

 

 

CO11-G1

660

349

43.5

1.23

43.5

1105

46.0

1168

37.5

952

 

 

CO11-G2

Shipped in two cartons as per above specifications

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POWER SUPPLY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model

BTUH

 

KW

 

HZ

 

Voltage 1O/

Amps

Wire

Phase

RPM-low

RPM-high

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CO11-G1

60,000

 

17.58

 

60

 

 

115

7.5

2

1

900

1,725

 

 

CO11-G1

60,000

 

17.58

 

60

 

208/240

4

2

1

1,140

1,725

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CO11-G1

60,000

 

17.58

 

50

 

 

230

4

2

1

950

1,425

 

 

CO11-G2

120,000

 

35.16

 

60

 

 

115

2 x 7.5

2

1

900

1,725

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CO11-G2

120,000

 

35.16

 

60

 

208/240

2 x 4

2

1

1,140

1,725

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CO11-G2

120,000

 

35.16

 

50

 

 

230

2 x 4

2

1

950

1,425

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GAS SUPPLY — 3/4" NPT rear connection

Gas Type

Manifold Pressure

Inlet Pressure

WC

Mbar

Inches

Mbar

 

Natural

3.5"

9 min

7"

17.5 min

Propane

 

 

11"

27.5 min

 

10"

25 max

13"

32.5 max

 

 

 

 

 

Separate gas connections or external manifold required for stacked ovens

MINIMUM CLEARANCES

 

Vent Hood

Direct Venting

 

 

Inches

MM

Inches

MM

 

Right

1

25

1

25

 

Left

1

25

3

76

 

Rear

3

76

3

76

 

Suitable for installation on combustible floors when installed on factory supplied legs or casters

 

BAKERS PRIDE OVEN COMPANY, INC.

Continuous product improvement is a policy of Bakers Pride Oven Company.

 

Therefore, specifications and design are subject to change without notification

BAKERS

30 Pine Street, New Rochelle, NY 10801

TS: 3M 11/04