CY7C1019BN
Document #: 001-06425 Rev. ** Page 2 of 8
Maximum Ratings
(Above which the useful life may be impaired. For user guide-
lines, not tested.)
Storage Temperature .................................–65°C to +150°C
Ambient Temperature with
Power Applied.............................................–55°C to +125°C
Supply Voltage on VCC to Relative GND[1].... –0.5V to +7.0V
DC Voltage Applied to Outputs
in High Z State[1]....................................–0.5V to VCC + 0.5V
DC Input Voltage[1].................................–0.5V to VCC + 0.5V
Current into Outputs (LOW).........................................20 mA
Static Discharge Voltage............................................>2001V
(per MIL-STD-883, Method 3015)
Latch-Up Current.....................................................>200 mA
Selection Guide
7C1019BN-12 7C1019BN-15 Unit
Maximum Access Time 12 15 ns
Maximum Operating Current 140 130 mA
Maximum Standby Current 10 10 mA
L 1 1 mA
Operating Range
Range Ambient
Tempe ratur e[2] VCC
Commercial 0°C to +70°C 5V ± 10%
Industrial –40°C to +85°C 5V ± 10%
Electrical Characteristics Over the Operating Range
Parameter Description Test Conditions
-12 -15
UnitMin. Max. Min. Max.
VOH Output HIGH Voltage VCC = Min., IOH = – 4.0 mA 2.4 2.4 V
VOL Output LOW Voltage VCC = Min., IOL = 8.0 mA 0.4 0.4 V
VIH Input HIGH Voltage 2.2 VCC+ 0.3 2.2 VCC+ 0.3 V
VIL Input LOW Voltage[1] –0.3 0.8 –0.3 0.8 V
IIX Input Leakage
Current GND < VI < VCC –1 +1 –1 +1 µA
IOZ Output Leakage
Current GND < VI < VCC,
Output Disabled –5 +5 –5 +5 µA
ICC VCC Operating
Supply Current VCC = Max., IOUT = 0 mA,
f = fMAX = 1/tRC
140 130 mA
ISB1 Automatic CE
Power-Down Current
—TTL Inputs
Max. VCC, CE > VIH
VIN > VIH or
VIN < VIL, f = fMAX
40 40 mA
L20 20
ISB2 Automatic CE
Power-Down Current
—CMOS Inputs
Max. VCC,
CE > VCC – 0.3V,
VIN > VCC – 0.3V,
or VIN < 0.3V, f = 0
10 10 mA
L1 1
Capacitance[3]
Parameter Description Test Conditions Max. Unit
CIN Input Capacitance TA = 25°C, f = 1 MHz,
VCC = 5.0V 6pF
COUT Output Capacitance 8 pF
Notes:
1. VIL (min.) = –2.0V for pulse durations of less than 20 ns.
2. TA is the “Instant On” case temperature.
3. Tested initially and after any design or process changes that may affect these parameters.
[+] Feedback