10/100 Fast Ethernet Switch User’s Guide
Connecting The Switch
19
Figure 4-4. DES-3208 Switch to switch connection using the
straight OR crossover cable options.
Using straight cable
When using straight cable, this is done from the uplink (MDI-II) port of the
Switch (Switch A) to any of the 10 Mbps or 100 Mbps (MDI-X) port of the
other switch (switch B) or other devices (see figure 4-4).
Using crossover cable
When using crossover cable, this is done from any (MDI-X) port of the
Switch (Switch A) to any of the 10 Mbps or 100 Mbps (MDI-X) port of the
other switch (switch B) or other devices (see figure 4-4).
Switch A’s LED indicators for the respective connected ports are as follows:
100M is ON for 100Mbps, otherwise OFF.
Link/Act is ON.
FDX/Col depends on the connected switch or other device.