D-Link DFM-560EL External Modem

User’s Guide

 

 

WARNING

ONLY CONNECT EQUIPMENT WITH A TELECOMMUNICATIONS

COMPLIANCE LABEL

WARNING

FOR SAFETY REASONS, ONLY CONNECT EQUIPMENT WITH A

TELECOMMUNICATIOS COMPLIANCE LABEL. THIS INCLUDES

CUSTOMER EQUIPMENT PREVIOUSLY LABELLED

PERMITTED OR CERTIFIED.

Modems connected to the Australian telecommunications network must be marked in accordance with the Labeling Notice. This modem has been specifically configured to ensure compliance with the ACA Standards. Do not adjust your modem or software outside the values indicated as below. To do so would result in your modem being operated in a non-compliant manner.

Modem Commands:

Command

Default

Permissible Range

ATA

-

Do not use

ATB

B0

Do not set to B1

AT&G

&G0

&G2

AT&P

&P0

&P1

ATSn

see table below

 

S register

Default

Permissible Range

s6

2

2 to 6

Call Attempts/Retries:

Applications software shall be configured so that no more than 3 attempts are made to

establish a connection to a given number (Note: if the modem can detect service tones, up to 10 attempts can be made). If the call sequence is unsuccessful, there shall be a delay of at least 30 minutes before attempting to call the number again.

Failure to set the modem and any application software used with the modem, to the values shown as above will result in the modem being operated in a non-compliant manner.

Consequently, this would be in violation of the Labeling Notice for this equipment, and the Telecommunications ACT 1997 prescribes penalties for the connection of non-compliant equipment.