Installation Specifications

Cabinet and Countertop Layout

wARNING

Failure to meet or exceed the maximum and minimum dimensions/clearances stated in these instructions may result in a fire hazard.

Follow the countertop manufacturer’s instructions regarding the minimum corner radius, use of heat reflective tape, reinforcement of corners, etc.

Carefully check the location where the cooktop will be installed. For best performance, the cooktop should be placed away from drafts that may be caused by doors, windows and heating and air conditioning outlets.

This appliance is to be used in conjunction with a suit- able vent hood or approved Dacor raised vent system.

All tolerances +1/16” (+1.6 mm), -0 unless otherwise noted.

A

13” max.3

 

(33.0 cm)

 

 

18” min.1, 3

 

(45.7 cm)

Combustible

30” min.1, 2

surface to rear

(76.2 cm)

See cutout

 

dimensions

 

 

1 5/8” min.

 

(4.1 cm)

 

See cutout

 

dimensions

1Distance to combustible surfaces measured from cooking surface (top of cooktop grate).

2If installing with an overhead range hood, check the hood specifications for minimum required clearances.

3This specification does not apply for cabinets located greater than a horizontal distance of 5 1/2” (14.0 cm) from edge of cooktop. Allow 6 7/8” (17.5 cm) from cutout edge.

Minimum Required Clearances Around the Cooktop

Model

(A) Minimum(A) Recommended

DCT305

30” (76.2 cm)

36” (91.4 cm)

DCT365

36” (91.4 cm)

42” (106.7 cm)

Allow a minimum 1/4” (6 mm) clearance between the bottom of the cooktop chassis and all combustible sur- faces, including the upper edge of a drawer installed below the cooktop.

 

1/4” (6 mm)

 

mimimum clearance

B

to combustible

 

surfaces

* Allows for clearance between hold down brackets

Model (B) Minimum

DCT305 29 1/4” (74.3 cm)

DCT365 35 1/4” (89.5 cm)

Under Cabinet Clearances

The gas supply piping, gas shut-off valve and the elec- trical outlet must be located so that they do not inter- fere with the cooktop when it is installed. If installing another appliance in the cabinet below, allow for the routing of gas and electrical service behind it.

The installation must allow for the following:

Access to the gas shut-off valve and regulator when the unit is installed.

Access to the electrical outlet when the cooktop is in place. The 42” (106.7 cm) power cord must be able to reach the electrical outlet.

Access to the underside of the cooktop for service and inspection purposes.

Clearance inside the cabinet to allow for proper hold down bracket installation.

To allow access to the utilities and cooktop bottom, a fixed shelf should not be installed below the cooktop. See the following pages for countertop cutout dimensions.

Raised Vent Compatibility

Model DCT305 is not compatible with a raised vent. If installing cooktop model DCT365 with a raised vent, install only Dacor raised vent model ERV3615. Installation of any other raised vent model may cause improper operation.

5