Installation Specifications
Cutout Dimensions
Vertical combustible surface
All tolerances +1/16”
Rear wall
4 1/4” (10.8 cm) min. | F |
from mounting surface to | |
combustibles below |
|
cooktop chassis |
|
C
D
1 5/8” min.
(4.1 cm)
E
F
Minimum distance to combustible side wall above countertop (both sides)
Countertop Cutout Dimensions
Installation Type | (C) Minimum | (D) | (E) | (F) Minimum |
DCT305* | 3 1/4” (8.3 cm) | 19 5/8” (49.9 cm) | 27 5/8” (85.4 cm) | 6 7/8” (17.5 cm) |
DCT365 with no raised vent | 3 1/4” (8.3 cm) | 19 5/8” (49.9 cm) | 33 5/8” (85.4 cm) | 6 7/8” (17.5 cm) |
DCT365 with ERV3615 raised vent | 3/8” (1.0 cm) | 22 3/4” (57.8 cm) | 33 5/8” (85.4 cm) | 6 7/8” (17.5 cm) |
* Model DCT305 is not compatible with a raised vent
3/8” min. (1.0 cm)
flat countertop overhang Countertop required behind cutout
Stiffener DCT365 cooktop
Cabinet face
3/8” min. (1.0 cm) space behind raised vent chassis to clear stiffener
ERV3615 raised vent. Check raised vent dimensions/specifications to determine proper fit
Floor
Side View - DCT365 Cooktop with ERV3615 Raised Vent