Installation Instructions
Verify Package Contents
•Hold down brackets (2)
•Grates (3)
•Burner sets (5)
•Gas pressure regulator with 3/4” to 1/2” reducer
•Stainless steel cleaner
Installing the Cooktop
wARNING
•Verify that the power supply meets the specifications on page 4 before proceeding.
•To prevent damage to the gas pressure regulator, install it only after the cooktop is mounted in its perma- nent position.
caution
•Do not
•Do not use a hardening compound or caulk to perma- nently seal the cooktop into place. The cooktop must be readily removable if service is required. Removal of sealant to service the unit will be performed at the customer’s expense.
1.If the cooktop will be used with a raised vent, install the vent according to it’s installation instructions first.
2.Lower the cooktop into the cutout. Slide it forward as far as possible and center it side to side.
3.Secure the cooktop to the countertop using the two (2) provided
Hold down |
|
bracket mounting holes |
|
(both sides) | Gas inlet |
| |
| Power cord |
Connecting the Gas Line
wARNING
•Verify that the gas supply meets specifications before connection. See page 4.
•Do not install the cooktop without also installing the included gas regulator. Do not use the cooktop without the regulator installed.
•Ensure that the arrow on the regulator points in the direction of the gas flow, towards the cooktop.
•Do not apply excessive pressure when tightening gas connections and fittings.
•Do not use Teflon tape, pipe thread sealant or any other sealing compound on the seat of flared gas line connections.
•Test the gas lines for leaks as instructed before use. Do not use a flame to check for leaks.
•The maximum gas supply pressure to the regulator must never exceed 1/2 psi (3.5 kPa).
•The cooktop and
•The cooktop must be isolated from the gas supply pip- ing system by closing the
•For LP gas installations, the LP gas tank must have its own
1.Attach the gas pressure regulator (included with the cooktop) to the cooktop pipe nipple inlet. For tight installations, the regulator may be installed upstream from the pipe nipple, anywhere between the
2.Complete connection of the gas supply to the cooktop by installing a minimum 1/2” flexible gas line (not included) between the pressure regulator and the shut- off valve.
3.Check for gas leaks:
◊Turn all cooktop control valves to the OFF position.
◊Turn on the gas supply valve and check all lines and connections for leaks using a soap and water solution or a gas leak detector.
◊Turn the gas supply off.
7