Installation Specifications

WARNING

This appliance must be installed and electrically grounded in conformance to local codes.

In the absence of local codes, the appliance installation must conform with the National Fuel Gas Code, ANSI Z223.1/NFPA 54 and the National Electrical Code, ANSI/NFPA 70.

Installation of this range in a manufactured (mobile) home must conform with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 [formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD (Part 280)] or with local codes where applicable.

This range is not designed for installation in a recreational vehicle.

Do not obstruct flow of combustion and ventilation air.

To prevent an electric shock hazard, the power supply must meet the specifications stated below. It is the owner’s responsibility to make sure that the electrical service meets electrical requirements and that the electrical outlet has been properly installed by a licensed electrician.

Electrical Power Supply Requirements

The range is supplied with a factory installed, 6 foot long, power cord with a three-prong grounding plug. It is connected to the chassis at the rear of the range. It must be connected to a dedicated, grounded three- prong electrical outlet installed by a licensed electrician.

The correct voltage, frequency and amperage must be supplied to the electrical outlet according to the product data label (see inside cover for location). The Electrical Supply Requirements provided below are for reference.

Electrical Circuit

Total Connected Load

Required

 

120 Vac 60 Hz,

0.5 kW

15 Amp.

(4.0 Amp.)

Electrical Supply Requirements

IMPORTANT: The above information is for reference only. If the information above differs from the information on the product data label on the appliance, use the information on the label.

Gas Supply Requirements

Be certain that the range being installed is correct for the gas service being provided (natural gas or LP gas).

An external manual shut-off valve must be installed between the gas inlet and the range for the purpose of turning on or shutting off gas to the appliance.

The range comes from the factory with the regulator installed. Use only the installed regulator.

The gas inlet on the regulator accommodates a 1/2” NPT gas line connection. The range can also accommodate a 3/4” NPT gas line connection by removing the 1/2” to 3/4” adapter on the regulator inlet.

Gas

Manifold

Min. Gas Supply

Max. Input

Pressure*

Type

Pressure (WC)

Pressure

(WC)

 

 

 

Natural

5”

6”

1/2 psi

LP

10”

11”

1/2 psi

Gas Supply Requirements

*The gas supply pressure for testing the regulator setting shall be at least 1 inch water column (249 Pa) above the specified manifold pressure.

IMPORTANT: The information above is for reference only. If the above data does not agree with the product data label, use the data on the label. See the inside cover for location.

The gas connection is located on the back of the unit as shown below.

121/4”

(31.1 cm)

to

Gas

Power

14 1/4”

(36.2 cm)

connection

cord

4 1/4”

(10.8 cm)

5