Installation Specifications
Rough-In Dimensions
◊A grounded 3 prong
See “Electrical Requirements” for additional information.
◊The plumbing for the water line can come through the floor flush to or from the back wall. See “Water Supply Requirements” for more information.
36”
701/2” Minimum
24”
Electrical Requirements
WARNING
Electrical shock Hazard – Plug into a grounded 3- prong
A 115VAC, 60 Hz, 15 Amp circuit breaker and electrical supply are required. A separate dedicated
Your Dacor® refrigerator is equipped with a 40” (1016mm)
IMPORTANT: A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation.
Water Supply Requirements
◊All installations must meet local plumbing code requirements.
◊Connect to 1/4” (6mm) copper line to the house cold fresh water supply.
◊Use a shut off valve between the refrigerator and supply. The shut off valve should be a drilled saddle valve.
◊Do not use a
◊Allow a minimum of 24” (610mm) diameter service loop of copper tubing outside the wall or floor for easy connection to the water supply.
Cold water supply
Connect the ice maker to a cold water line with water pressure between 30 and 120 PSI. If you have any questions about your water pressure, call your utility company.
IMPORTANT:
◊In homes with a Reverse Osmosis water treatment system, remove the water inlet connector from the “yellow” valve and attached to the “blue” valve. Make sure the water filter bypass plug is in place.