Dacor IF42DBOL Electrical Requirements, Recommended Grounding Method, Installation Requirements

Models: EF42DBSS IF42DBOL

1 24
Download 24 pages 54.18 Kb
Page 6
Image 6
Location Requirements (continued)

Installation Requirements

Location Requirements (continued)

ƒƒ A grounded 3 prong electrical outlet should be placed within 4” (10.2 cm) of the right side cabinets or end panel. See Electrical Requirements for more information.

ƒƒ The water shutoff should be located in the base cabinet on either side of the refrigerator or some other easily accessible area. If the water shutoff valve is not in the cabinets, the plumbing for the water line can come through the floor or the back wall. See Water Supply Requirements for more information.

Electrical Requirements

Electrical RequirementsWARNING

Electrical Shock Hazard

4”

(10.2 cm)

83 1/2” (212.1 cm) min.

84 3/4” (215.2 cm)

to bottom of solid soffit

77” (195.6 cm)

A Width

(see chart following)

See page 5

Plug into a grounded 3 prong outlet. Do not remove ground prong.

Do not use an adapter.

Do not use an extension cord.

Failure to follow these instructions can result in death, fire, or electrical shock.

Before you move your refrigerator into its final location, it is important to make sure you have the proper electrical connection.

Recommended Grounding Method

A 115 Volt, 60 Hz., AC only 15 or 20-amp fused, grounded electrical supply is required. It is recommended that a separate circuit serving only your refrigerator be provided. Use an outlet that cannot be turned off by a switch. Do not use an extension cord.

IMPORTANT: If this product is connected to a GFCI (Ground Fault Circuit Interrupter) equipped outlet, nuisance tripping of the power supply may occur, resulting in loss of cooling. Food quality and flavor may be affected. If nuisance tripping has occurred, and if the condition of the food appears poor, dispose of it.

NOTE: Before performing any type of installation, cleaning, or removing a light bulb, remove the top grille and turn the master power switch to OFF or disconnect power at the circuit breaker box.

When you are finished, turn ON the main power switch or reconnect power at the circuit breaker box. Then reset the control to the desired setting.

 

 

 

24”

 

 

(61.0 cm) min.

 

 

 

 

Model SeriesCutout Width A

EF42, IF42

41½” (105.4 cm) to 41¾” (106.1 cm)

EF48, IF48

47½” (120.7 cm) to 47¾” (121.3 cm)

NOTE: Flooring under refrigerator must be at same level as the room. Face of cabinetry must be plumb.