Dacor MCS127 Installation Specifications, Verifying the Package Contents, Installation Planning

Models: PCS130 MCS130 MCS127 PCD230 ECS127 ECD227 ECD230 ECS130 MCD230 MCD227

1 16
Download 16 pages 51.46 Kb
Page 7
Image 7
Installation Specifications

Installation Specifications

Verifying the Package Contents

Verify that all required components have been provided. If any item is missing or damaged, please contact your dealer immediately. Do not install a damaged or incomplete appliance.

Mounting Screws

Use and Care Videotape

Oven Racks

Broiler Grill and Pan

Exhaust Grill/Lower Trim

Rear Top Trim

GlideRack™ Oven Rack

Light Lens Pry Stick

Installation Planning

A qualified technician must complete the installation of this built-in appliance. Proper installation is your responsibility.

Carefully check the location where the oven is to be installed. The oven should be placed for convenient access. Make certain that electrical power can be provided in the selected location.

Plan the installation so that all minimum clearances are met or exceeded. Dimensions shown provide minimum clearances, unless otherwise noted. Be certain that proper clearance is provided for the oven door when it is in the open position.

The specified minimum cabinet depth and width must be provided. The cabinet depth and width must completely enclose the recessed portion of the oven.

Cabinet cutout dimensions must be used as indicated. All contact surfaces between the appliance and the cabinet must be solid and level. The oven support platform must be flush with the bottom edge of the cabinet cutout.

Make certain that you have everything necessary to ensure a proper installation before proceeding.

Installing the Support Platform in the cabinet

Provide a platform within the cabinet upon which the oven will be supported. The platform must be installed level and straight. The top edge of the platform must be flush with the cutout at the front of the cabinet. There are no provisions to level the oven after it has been installed. 3/4” (19mm) thick plywood is recommended.

NOTE:

An oven that is not level may provide poor or inconsistent baking results.

Electrical Power Supply

Requirements

It is the owner’s responsibility to ensure that a qualified electrician performs the electrical connection of this appliance. The electrical installation, including minimum supply wire size, must comply with the National Electric Code ANSI/NFPA 70-1990* (or to the latest revision) and local codes and ordinances.

*A copy of this standard may be obtained from: National Fire Protection Association

1 Batterymarch Park

Quincy, Massachusetts 02269-9101

The correct voltage, frequency, and amperage must be supplied to the appliance from a separate, grounded, single phase circuit that is protected by a properly sized circuit breaker or time-delay fuse. If a time-delay fuse is utilized, fuse both sides of the line (L1 and L2).

The required voltage, frequency and amperage ratings are listed on the product data plate (located inside the intake grill to the left of the door latch) and in the Table below.

The correct voltage, frequency, and amperage must be supplied to the appliance from a separate, grounded, single phase circuit that is protected by a properly sized circuit breaker or time-delay fuse. If a time-delay fuse is utilized, fuse both sides of the line (L1 and L2).

The required voltage, frequency and amperage ratings are listed on the product name plate (located inside the intake grill to the left of the door latch) and in the Table below.

Verifying the Package Contents WARNING

WARNING – If the electrical service provided does not meet the product specifications, do not proceed with the installation. Call a licensed electrician to correct.

NOTES:

1.Preheat times and cavity temperature recovery times will be increased slightly if operating on a 120/208 volt power supply.

2.208V models should not be connected to 240V source power.

3.Power supply must be an isolated circuit.

5

Page 7
Image 7
Dacor MCS127, MCD227, MCD230, ECS130 Installation Specifications, Verifying the Package Contents, Installation Planning