Installation
Turning Off the Power Supply
Before attempting to connect the appliance to power, turn off the electrical power supply. Also, always turn off electrical power to the appliance prior to servicing it.
WARNING
WARNING – Failure to disconnect power may result in electrical shock or fire hazard.
Electrical Connection
WARNING
1.This appliance must be connected to a grounded, metallic, permanent wiring system. Alternatively, a grounding conductor should be connected to the grounding terminal or lead on the appliance. Failure to do so may result in an electrical shock hazard.
2.Do not install a fuse in the neutral or ground circuit. A fuse in the neutral or ground circuit may result in an electrical shock hazard.
Grounding Instructions
The appliance must be connected to the power supply with copper wire only. The use of aluminum wire may result in unsatisfactory connections. Flexible armored or
Be certain to locate the junction box such that the electrical supply may be easily disconnected in the event that service becomes necessary. Also, provide extra slack in the cable to allow the oven to slide forward for servicing.
This appliance must be electrically grounded.
With the oven positioned directly in front of the cabinet cutout, feed the appliance conduit to the electrical junction box. Then, depending upon local codes, utilize one of the following techniques to connect the appliance to the electrical power supply:
A. Connecting to a Four-Wire Electrical System
1.Separate the green and white appliance wires.
2.Connect the white appliance wire to the neutral (white) supply wire in the junction box.
3.Connect the black appliance wire to the black (L1) power supply wire in the junction box.
4.Connect the red appliance wire to the red (L2) power supply wire in the junction box.
5.Connect the green appliance wire to the green house grounding wire
Instructions
Cable from
power supply
| Junction | |
| box | |
RED | WHITE | |
RED | ||
WHITE | ||
| ||
GREEN | BLACK | |
GREEN | ||
BLACK | ||
| ||
| Wire nut | |
| (4 places) | |
Conduit from | ||
| appliance |
Connecting the Appliance to a Four-Wire Power Supply
WARNING
WARNING – Do not connect the green appliance wire to the neutral (white) junction box wire unless local building codes permit.
Cable from
power supply
| Junction |
| box |
RED | GREEN |
| |
RED | WHITE |
| WHITE |
| BLACK |
| BLACK |
| Wire nut |
| (3 places) |
| Conduit from |
| appliance |
Connecting the Appliance Ground to Supply Neutral
B.Connecting the Green Appliance Wire to the Neutral (White) Supply Wire – Where Local Codes Permit
1.Connect the green and white appliance wires to the neutral (white) supply wire in the junction box.
2.Connect the black appliance wire to the black (L1) power supply wire in the junction box.
3.Connect the red appliance wire to the black (L2) power supply wire in the junction box.
7