Planning the Installation
Location Planning - Enclosed Cabinets
•Maintain all minimum clearances specified on pages 7 and 8.
•For proper outdoor grill operation, provide a flat, level mounting surface with minimum 3/4” thickness.
•All models are designed to allow installation in combustible or
•On installations without a LP cylinder tank located below the unit, plan the installation so that the gas
Optional Finish Trim Kits
The optional finish trim can be installed on the countertop to finish the sides and back of the countertop opening. The stainless steel finish trim can be caulked to the countertop and should be secured to the base enclosure with flat head screws. Center the trim within the cutout dimensions noted in this manual, then utilizing the deck screws along with the holes located along the vertical sides of the finish trim, install them securely to the base enclosure countertop sub- straight. Install the trim before installing the grill.
Enclosed Cabinet Installations with a LP Cylinder
•When using a
•Plan to install the grill in a base structure that has one of the following structural details:
◊The LP cylinder valve shall be readily accessible for hand operation. A door on the enclosure to gain access to the cylinder valves is acceptable, provided it is
◊The enclosure for the
◊There shall be a minimum clearance of 2 inches (51mm) between the floor of the
10" (254mm) Min. to combustibles
1 1/4" (32mm) Min. to
28 1/2" (724mm)
To finished
countertop
Junction Box
Trim frame (accessory)
|
|
|
|
|
|
|
|
|
| Rotisserie mounting |
|
|
|
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
| bracket (factory installed)1/4" |
|
|
|
|
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| (6mm) |
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
3/4" (19mm) |
|
|
|
|
| 23 3/4" (603mm) |
|
|
|
|
|
|
|
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||
|
|
|
|
|
| 24" (610mm) |
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
min. to any |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
material* |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
See page 8 for overall cabinet dimensions
OB36, OBS36, OB52 and OBS52Cutout Dimensions - Side View10" (254mm) Min. to combustibles 2" (51mm) Min. to
Junction Box
Trim frame (accessory)
1/4"
(6mm)
23" (584mm)
3/4" (19mm) 24" (610mm) Min. to any
material*
See page 8 for overall cabinet dimensions
OBSB162 Cutout Dimensions -Side View•The design of the outdoor cooking enclosure must allow the
•Connections which may be disturbed when installing the cylinder in the enclosure can be leak tested inside the enclosure.
•Internal mounting means shall be provided on the outdoor gas grill for mounting the