Installation Instructions

Electrical Connection

WARNINGS

To avoid electrical shock or fire hazard, make sure the power supply at the fuse or junction box is turned off before proceeding with final installation.

Improper connection of the hood electrical wiring may create an electric shock or fire hazard and may result in damage to the hoods electrical system.

Do not ground the hood to the neutral (white) power supply wire. Connect the hood ground wire to a separate, properly grounded wire installed by a licensed electrician.

Connect the power supply wires to the wires coming out of the top of the hood junction box on the blower assembly:

1.Connect the white wire from the hood to the neutral (white) power supply wire.

2.Connect the black wire from the hood to the hot (black) power supply wire.

3.Connect the green and yellow wire from the hood to the house ground (green) wire from the junction box.

black to black

white to white

Yellow/green tO green

Install the Chimney

IMPORTANT: Be careful not to pinch the electrical wires while installing the chimney.

1.Remove the protective plastic covering from both pieces of the chimney assembly. Do not remove the protective tape strips from the inside of the chimney. They protect the telescoping pieces from scratching during installation.

2.Carefully slide both sections together so that only the vents on the top section show.

3.Hold the chimney vertically with the vents up, close to the blower assembly.

4.Connect the control panel cable on the chimney to the cable on the front of the blower assembly.

vent

connect cable

chimney