Preparing for Installation

warning

Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information.

Electrical Specifications

warning

Electrical and grounding connections must comply with the applicable portions of the national electrical code and/or other local electrical codes.

This dishwasher comes with an electrical cord with a three prong grounding plug

for a 120 Vac, 15 Amp. power supply. Plug it only into a 120 Vac, three prong, grounding electrical outlet located to either side of the dishwasher cutout.

If the cord is not long enough, or if a hard-wire installation is needed, follow the instructions on page 12.

Electrical Requirements

Electrical Circuit

15 Amp. 120 Vac, 60 Hz.

Requirements

dedicated, grounded, circuit.

Total Connected Load

11 Amp. @ 120 Vac, 60 Hz.*

*For reference only. For exact specifications see the product data label, located inside the right door jamb.

Grounding Instructions for a Cord- Connected Appliance

This appliance must be grounded. In the event of a malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. This appliance is equipped with a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is installed and grounded in accordance with all local codes and ordinances.

warning

Improper connection of the equipment- grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative if you are in doubt whether the appliance is properly grounded. Do not modify the plug provided with the appliance, if it will not fit the outlet, have a proper outlet installed by a qualified electrician.

Do not use an extension cord with this appliance.

Grounding Instructions for a Permanently Connected Appliance

This unit must be grounded to operate properly. It must be connected to a grounded metal, permanent wiring system, or an equipment-grounding conductor must be run with the circuit conductors and connected to the equipment grounding terminal or lead of the appliance.

Damage to the dishwasher could occur if it is not properly grounded.

A three conductor electrical cable or conduit meeting local codes and ordinances is required. A UL listed strain relief is required if non-metalic cable is used. Suggested color coding: black, white and green.

Circuit Requirements

The wiring from the electrical outlet or junction box shall be connected to a circuit protected by a 15 Amp. circuit breaker or time delay fuse, installed by a licensed electrician.

Water Supply Specifications

warning

In order to prevent heat damage, all solder connections for the water line connected to the water supply valve must be made before the dishwasher water supply line is connected.

The dishwasher can be connected to a cold or hot water supply (maximum 160°F, 70°C). Dacor recommends using a hot water supply of 120°F (49°C) to 140°F (60°C). If a cold water supply is used, the washing times will be longer, but the performance will not be affected.

The water supply pressure must be between 4.2 and 140 psi (30 - 1000 kPa). The water supply line and the shut-off valve must supply a flow volume of at least 3 gallons (12 liters) per minute.

Install a 3/8” water supply valve for connection to the dishwasher’s water supply line in a location where it is easily accessible after the dishwasher is installed.

The dishwasher water supply line is equipped with a 3/8” (1.0 cm) NPT female compression fitting on the end.

4