WARNING:
**Do not connect the green appliance wire to the neutral (white) supply wire unless local building codes permit.
4. | Connect the red appliance wire to the red |
| (L2) power supply wire in the junction box. |
5. | Connect the green appliance wire to a |
| grounded supply wire in the junction box or |
| to a grounded cold water pipe. |
6. | If connecting to a grounded cold water |
| pipe, a separate copper grounding wire |
5.The maximum gas supply pressure to the appliance gas pressure regulator must never exceed 1/2 pound per square inch (3.5kPa).
Cable from
power supply
RED | GREEN |
| |
RED | WHITE |
| WHITE |
| BLACK |
| BLACK |
Conduit from | |
| appliance |
Junction box
Wire nut (3 places)
(No. 10 minimum) must be connected to a |
grounded cold water pipe by means of a clamp and then to an external grounding connector screw.
6.A grounded cold water pipe must have metal continuity to electrical ground and must not be interrupted by insulating materials. Any insulating materials must be jumped with a length of No. 4 copper wire securely clamped to bare metal at both ends.
Gas Connection
Before sliding the range into the cabinet, connect a flexible gas connector to the gas
NOTE:
The applaince gas pressure regulator is
Installing the Range
**Connecting the appliance to a
(RSE/MRES30 Only)
WARNING:
The RSD30 cannot be connected as above because it will damage the spark module.
B.Connecting the Green Appliance Wire to the Neutral (White) Supply Wire – Where Local Codes Permit. (RSE/MRES30
Only)
1.Connect the green and white appliance wires to the neutral (white) supply wire in the junction box.
2.Connect the black appliance wire to the black (L1) power supply wire in the junction box.
3.Connect the red appliance wire to the red (L2) power supply wire in the junction box.
C.Connecting the Green Appliance Wire to a Grounded Supply Wire or a Grounded
Cold Water Pipe – Where Local Codes Permit. (All Models)
1.Separate the green and white appliance wires.
2.Connect the white appliance wire to the neutral (white) supply wire in the junction box.
3.Connect the black appliance wire to the black (L1) power supply wire in the junction box.
WARNINGS:
1.Do not apply excessive pressure when tightening gas connections and fittings.
2.Do not use teflon tape or plumber’s putty on gas flex line connections.
3.Turn all cooktop control valves to the “OFF” position. Turn on gas supply and check all lines and connections for gas leaks using a soap and water solution. Do not use a flame to check for leaks. After verifying that there are no gas leaks, turn off the gas supply to the range by turning the gas
4.For LP installations, the LP gas tank must have its own high pressure regulator. This is in addition to the pressure regulator provided with the range.
Measure from the floor to the countertop and adjust the leveling legs as required to position the top frame at the desired height, based on the cabinet and countertop installation. Carefully slide the range into position in the cutout. (The left rear leveling leg should engage the
When the range is to be installed as a
Installing the Burner Components
Remove the brass burner rings, porcelain burner caps, and porcelain gates from their shipping packages. Place each burner ring onto its corresponding burner base, being certain that the five alignment tabs slide into the matching notches in the base. Set each porcelain burner cap on top of its corresponding burner ring. Place each grate onto the top frame, being certain that the rubber feet are positioned in the
Cable from |
|
|
|
| |
power supply | Separate No. 10 (minimum) |
|
| ||
|
|
|
| ||
| Junction | copper grounding wire |
|
|
|
|
|
|
|
| |
| box |
|
| No. 4 |
|
|
|
|
| copper wire | Meter |
|
|
|
|
| |
RED | WHITE |
|
|
|
|
RED |
|
|
|
| |
WHITE |
|
|
|
| |
|
|
|
|
| |
GREEN | BLACK | Clamp must be |
|
|
|
GREEN | Metal |
|
| ||
BLACK | tight on pipe |
| Clamps | ||
|
| ||||
| Wire nut |
| water pipe |
| Bare metal |
|
|
|
| ||
| (4 places) |
|
|
|
|
Conduit from
appliance
Connecting the appliance ground to a grounded junction box wire or grounded cold water pipe
locating dimples.
WARNING:
Never attempt to operate the cooktop section of the range with any of the burner rings, burner caps or grates removed.