![Reset(8)](/images/new-backgrounds/51138/5113857x1.webp)
Reset(8)
MICOM
18
R4
5.6K
+
CE5
4.7∝ F
50V
5V
IC6
7042P
DESCRIPTION
Voltage less than about 0.8V put in Micom Terminal of Number 18 and then Micom reset. Reset IC detect Power ON and Voltage less than 4.25V, and then send Reset Signal.
4.25V
DELAY TIME
FOR POWER ON
H
L
POWER
ON
Vcc (+5V)
t
RESET
t
28