Dehumidification Mode
1DT+1˚C < RT
Outdoor Fan, Compressor : ON
Indoor Fan : Low speed
Outdoor Fan, Compressor : 3 min/ON, 5 min/OFF
Indoor Fan : Low speed
Outdoor Fan, Compressor : OFF
Indoor Fan : Low speed
Air Discharge Direction
1.Press fan direction button to select fan direction
•Press desired fan direction button, "UP • DOWN" or "LEFT • RIGHT" control louver moves, press again to stop
Quick Mode(Powerful Cooling & Heating)
FAN DIR.
FAN DIR.
(1) Cooling Mode
* When the room temperature is higher than 22˚C or equal to 22˚C
1Fan Speed: high speed (Fixed)
2Air discharge direction: The control is available.
3Set temperature: 18°C (Fixed)
(1) Heating Mode
*When the room temperature is lower than 22˚C
1Fan Speed: high speed (Fixed)
2Air discharge direction: The control is available.
3Set temperature: 32°C (Fixed)
Self-Diagnostic Function
The control will contain diagnostic test to verify the integrity of the system.
(1) Error Code Display : RT (Room Temperature) LED
ERROR CODE | DISPLAY | ERROR CONTENTS | |
|
|
| |
1 | “E2” | Indoor unit sensor open or short | |
|
|
| |
2 | “E2” | Outdoor unit sensor open or short | |
|
|
| |
3 | “E3 ” | Compressor, Electrical parts of | |
comp. Gas leak | |||
|
| ||
|
|
|
17