Daewoo DPB-280LH Dehumidification Mode, Air Discharge Direction, Self-DiagnosticFunction

Models: DPB-280LH

1 51
Download 51 pages 55.17 Kb
Page 18
Image 18
Dehumidification Mode

Dehumidification Mode

1DT+1˚C < RT

Outdoor Fan, Compressor : ON

Indoor Fan : Low speed

2DT-1˚C < RT < DT+1˚C

Outdoor Fan, Compressor : 3 min/ON, 5 min/OFF

Indoor Fan : Low speed

3DT-1˚C > RT

Outdoor Fan, Compressor : OFF

Indoor Fan : Low speed

Air Discharge Direction

1.Press fan direction button to select fan direction

Press desired fan direction button, "UP • DOWN" or "LEFT • RIGHT" control louver moves, press again to stop

Quick Mode(Powerful Cooling & Heating)

FAN DIR. Air Discharge Direction

FAN DIR.Quick Mode(Powerful Cooling & Heating)(1) Cooling Mode

(1) Cooling Mode

* When the room temperature is higher than 22˚C or equal to 22˚C

1Fan Speed: high speed (Fixed)

2Air discharge direction: The control is available.

3Set temperature: 18°C (Fixed)

(1) Heating Mode

*When the room temperature is lower than 22˚C

1Fan Speed: high speed (Fixed)

2Air discharge direction: The control is available.

3Set temperature: 32°C (Fixed)

Self-Diagnostic Function

The control will contain diagnostic test to verify the integrity of the system.

(1) Error Code Display : RT (Room Temperature) LED

ERROR CODE

DISPLAY

ERROR CONTENTS

 

 

 

1

“E2”

Indoor unit sensor open or short

 

 

 

2

“E2”

Outdoor unit sensor open or short

 

 

 

3

“E3 ”

Compressor, Electrical parts of

comp. Gas leak

 

 

 

 

 

17

Page 18
Image 18
Daewoo DPB-280LH Dehumidification Mode, Air Discharge Direction, Quick ModePowerful Cooling & Heating, Cooling Mode