Fan Speed
(1)Motor speed (high speed, normal speed, low speed).
(2)Remote controller setting fan speed. (H, M, L)
(3)Relation of operating mode between fan speed.
| FAN ONLY | COOL | TURBO |
|
|
|
|
H | H | H | H |
M | M | M | - |
L | L | L | - |
|
|
|
|
Sleep Mode
(1)When you are going to sleep, select sleep button in remocon and the unit controls the room to the desired temperature. (The unit will not operate after 4 hour)
(2)For changing the temperature.
•Mode I (L1)
Difference
desired temperature between room temperature (° C)
|
|
| 1°C |
|
|
| 1°C |
|
|
Desired | 1°C |
|
|
|
|
|
|
| |
Temperature |
|
|
|
|
| 0 | 0.5 | 1.0 | HOUR |
SET TIME |
|
|
|
•The unit will not operate after 4 hour.
•Mode II (L2)
SET ON
SET OFF
Desired Temperature
+1˚C +1˚C
2hr 2hr 2hr 2hr 2hr
• The unit will not operate perfectly after 10 hour.
(3)To cancel sleep mode, press the SLEEP button again or press the MODE button once. : the SLEEP indicator will disappear in the display.
3min. Time Delay of Compressor
In normal operation, there is a time delay of three minutes between turn off and turning back on including initial power up.
10