Daewoo DWC-121R service manual Only Compressor Do not Run

Models: DWC-121R

1 41
Download 41 pages 21.21 Kb
Page 20
Image 20
Only Compressor Do not Run
Check the compressor wiring

Only Compressor Do not Run

- Check the following at cooling mode

Check the voltage between “POWER 1 ”

Rating voltage

 

and

 

“RL1 3

less than 90%

of Main P.C.B

 

Rating voltage more than 90%

Rating voltage

less than 90%

Rating voltage more than 90%

Check the Relay(RL1)

NG

 

Check the wiring of outdoor unit

Check the compressor

Open or Short

(Check the winding resistance)

 

 

 

 

OK

Check the compressor capacitor

Check the Main P.C.B

the circuit for relay

driving.

Check the connecting

wire between Main

P.C.B and the

compressor

Change Relay(RL1)

Change the compressor.

19

Page 20
Image 20
Daewoo DWC-121R service manual Only Compressor Do not Run