Sensor(3)
Room temperature Sensor Input
MICOM
15
DESCRIPTION
Vcc
| 2 |
R4 | 1 |
|
300
R3
C13 12.7K
0.01
Number 15 of Micom is Terminal of A/D convertor Input.
Room temperature is sensing by change of Thermister Resistance, Micom is put in 5V by ratio between R3 (12.7KΩ ) and Room sensor.
Relation between temperature and voltage is following Table
C13 is Noise filter.
Temperature | Voltage (V) |
| |
(°C) | No. 15 |
| |
|
|
4.06 | |
|
|
0 | 3.60 |
|
|
15 | 2.76 |
|
|
25 | 2.20 |
|
|
40 | 1.48 |
|
|
| Table |
23