Check the following points before calling your local authorised Service Centre.

GB

PROBLEMS

The appliance is operating in dehumidifying mode, but the humidity does not decrease.

CAUSE

The filter is blocked.

The temperature or humidity in the room are too low.

The room is too big for the dehumidifying power of the appliance.

Too many sources of humidity in the room (pots of boiling water, etc.).

The humidy set point is too high.

SOLUTION

Clean the filter.

In certain conditions, it is nor- mal for the appliance not to dehumidify (in certain cases, it is recommended to heat the environment).

Decrease the humidity set point.

The appliance does not work for 3 minutes after start-up.

The safety device has tripped.

Wait for 3 minutes to pass.

is displayed

is displayed

E2”/”E3” is displayed

Symbol “PUMP” is displayed

The tank is missing.

Replace the tank.

The tank is full.

Empty the tank.

The tank is incorrectly

Position the tank correctly.

positioned.

 

The temperature in the room is

Increase room temperature.

very low.

 

One of the sensors on the

Call the Service Centre.

appliance is faulty.

 

The condensation discharge

Check the hose is correctly

pump is missing.

positioned.

 

Disconnect and reconnect the

 

plug.

9