1)Remove the continuous drain cap 1 by turning it counterclockwise then remove the rubber stopper from the spout 2 (fig. 2).

fig. 5

2

1

fig. 2

2)Insert the drain cap 1 in the condensate drain hose (8) till the end (fig. 3) then screw the cap into the spout. (fig. 4).

fig. 3

3)Make sure the end of the hose is no higher than the spout (Fig. 3) or water could remain in the tank. Make sure there are no kinks in the hose (Fig. 5).

Keep the rubber stopper to close the spout.

C)Continuous draining using the pump (only on pump models)

The patented heavy-duty pump system allows water removal of up to 13 ft (4m) in height.

If you want the water to flow directly to a drain, connect the condensation discharge tube supplied

(9) to the connection pipe located on the

lower front part of the unit unit (you will first need to remove the stopper labeled PUMP) (fig. 6). Select the dehumidifying function and press the PUMP button.

Note: With the condensation discharge hose missing and the pump switched ON, the display will show the symbol PUMP blinking.

To eliminate this problem:

Check the hose is correctly positioned;

Disconnect and reconnect the plug.