7. TROUBLE SHOOTING
1)Error Code 1(Er)
1 Check the connector of room air thermistor. (or connecting wire)
2Check soldering of connecting on control P.C.B. (Error of soldering or short) 3Check the resistance of room air thermistor.
“Press the temperature Keys (Up & Down), Error code is displayed.”
Unit Not Run
The power is applied to the unit
Check the voltage between “POWER 1 ”
and
“RL1 4 ” of Main P.C.B
Rating voltage
under 90%
Check the
Breaker or Fuse
Rating voltage more than 90%
Check the unit display
is all off?
Yes
Press the ON/OFF button of Remote Control or Front Panel
Is the unit display all off?
Pull out the power plug
and then insert the power plug
after 5 second
No
No
Self Diagnostic function is ON
Yes
Check according to
self Diagnostic function
Main P.C.B defect
No |
Main P.C.B is normal
Recheck from the beginning
18