TROUbLESHOOTING

E-6

 

 

 

 

Observe all Safety Guidelines detailed throughout this manual

 

PRObLEMS

POSSIbLE

(SYMPTOMS)

CAUSE

 

 

 

OUTPUT PRObLEMS

 

Machine has maximum weld out-

1.

LOCAL/REMOTE Switch (S3)

 

 

put and no control.

 

in wrong position.

 

 

2.

LOCAL/REMOTE Switch (S3)

 

 

 

is faulty, or an open lead going

 

 

 

to the LOCAL/REMOTE Switch

 

 

 

(S3).

 

 

 

 

 

VRD passes self test and green

1.

Too much cable inductance.

 

light is on, but machine will not

 

 

 

Weld.

 

• Uncoil output cables, shorten

 

 

 

cable length, or wrap work and

 

 

 

electrode cables together.

 

 

2.

Too much cable.

 

 

 

• Maximum cable length (work

 

 

 

and electrode) is approximately

 

 

 

300 feet.

 

 

3.

Buildup on stick electrode.

 

 

 

Clean or replace electrode.

 

 

4.

Possible shorted bridge rectifier,

 

 

 

if pilot light is off.

 

 

5.

Fault detected after self test.

 

 

 

Cycle power to reset machine.

 

 

 

 

 

 

 

 

RECOMMENDED

COURSE OF ACTION

If all recommended possible areas of possible cause have been checked and the problem persists,

Contact your local Lincoln Authorized Field Service Facility.

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.