Lincoln Electric IM10018-A manual PRObLEMS Symptoms

Models: IM10018-A

1 55
Download 55 pages 15.79 Kb
Page 36
Image 36

E-9

TROUbLESHOOTING

E-9

 

 

 

 

 

Observe all Safety Guidelines detailed throughout this manual

 

 

 

 

 

 

PRObLEMS (SYMPTOMS)

The weld output terminals are always electrically "hot".

POSSIbLE

CAUSE

OUTPUT PRObLEMS

1.Remove any external leads hooked to #2 and #4 on the ter- minal strip or any connections to the 14 pin MS connector. Set OUTPUT TERMINALS switch to the OFF position. If the problem disappears the fault is in the control cable or wire feeder.

2.If some open circuit voltage is present (over 3VDC.) after per- forming Step #1. then the prob- lem is within the IDEALARC® DC-600 VRD.

RECOMMENDED

COURSE OF ACTION

If all recommended possible areas of possible cause have been checked and the problem persists,

Contact your local Lincoln Authorized Field Service Facility.

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

IDEALARC® DC-600 VRD

Page 36
Image 36
Lincoln Electric IM10018-A manual PRObLEMS Symptoms