TROUbLESHOOTING | |||
|
|
|
|
| Observe all Safety Guidelines detailed throughout this manual |
|
|
|
|
|
|
PRObLEMS (SYMPTOMS)
The weld output terminals are always electrically "hot".
POSSIbLE
CAUSE
OUTPUT PRObLEMS
1.Remove any external leads hooked to #2 and #4 on the ter- minal strip or any connections to the 14 pin MS connector. Set OUTPUT TERMINALS switch to the OFF position. If the problem disappears the fault is in the control cable or wire feeder.
2.If some open circuit voltage is present (over 3VDC.) after per- forming Step #1. then the prob- lem is within the IDEALARC®
RECOMMENDED
COURSE OF ACTION
If all recommended possible areas of possible cause have been checked and the problem persists,
Contact your local Lincoln Authorized Field Service Facility.
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
IDEALARC®