E-3

TROUbLESHOOTING

E-3

 

 

 

 

Observe all Safety Guidelines detailed throughout this manual

 

PRObLEMS

POSSIbLE

(SYMPTOMS)

CAUSE

 

OUTPUT PRObLEMS

Major Physical or Electrical

Contact the Lincoln Electric Service

Damage is Evident

Dept. (216) 383-2531 or 1-800-

 

833-9353 (WELD)

The Machine is dead- The Input 1.

Check for blown or missing

contactor does not operate.

fuses in input lines.

2.

Check the three- phase input

 

line voltage at the machine.

 

The input voltage must match

 

the rating plate and reconnect

 

panel.

3.

Power ON/OFF switch may be

 

defective.

4.

Rectifier bridge may be defec-

 

tive.

5.

VRD P.C. board may be defec-

 

tive.

RECOMMENDED

COURSE OF ACTION

If all recommended possible areas of possible cause have been checked and the problem persists,

Contact your local Lincoln Authorized Field Service Facility.

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

IDEALARC® DC-600 VRD

Page 30
Image 30
Lincoln Electric IM10018-A manual Output PRObLEMS