PRINCIPLE OF INTAKE & OUTLET OF THE AIR

INTAKE : ARMATURE moves up, and BELLOWS inhales the air. At the same time, protector B is open and A is close.

OUTLET : ARMATURE moves down, and BELLOWS exhausts the air. At the same time, protector B is close and A is opend.

FUNCTIONAL PRINCIPLE OF TRANS & MAGNET

¡The phase of A.C electric power changes to 60 cycle/second.

¡The magnetic pole of trans core is changed by the change of the phase of A.C electric power.

¡The core repeats push and pull (3600 times/min.) of the armature magnet.

A.C

N

S

NS

A.C

LEAF SPRING TRANS CORE

MAGNET

S

N

NS

FUNCTIONAL PRINCIPLE OF BUBBLE WASHING MACHINE

ACROSS SECTION

Air bubble

Tub

Outer tub

Pulsator

FUNCTIONAL PRINCIPLE

Bubble generator supplies the air from the bottom of outer tub to the inner space of pulsator, the air is dispersed by the rotation of pulsator. Air-bubble is created by the centrifugal force, and rises up.

EXPLANATION 15