Key Pad Features

Key Pad Features

LED DISPLAY: Displays the following information independently; Set Temperature, Ambient Room Temperature and Auto Timer On/Off settings.

POWER: Turns unit On / Off.

MODE MODE: Allows you to scroll through and select

the desired operating mode; Cool Choix du meilleur endroit , Dry Manual background,

Fan Only Manual background and *Auto Auto . The selected mode will be denoted by the adjacent indicator light. *‘Auto’ is a pre-set factory program that automatically defines the mode (Cool or Dry) and

 

LED

 

DISPLAY

Temp/Timer

 

Control

 

68

Auto

 

Timer

 

Sleep

Check

Mode

Filter

 

MISE EN GARDE

Comme le compresseur se trouve du côté des commandes de l'unité (côté droit), ce côté est plus lourd et plus difficile à manipuler. Un soutien inapproprié du côté des commandes de l'appareil peut causer des blessures et endommager l'appareil et d'autres biens mobiliers. C'est pourquoi il est recommandé que quelqu'un vous aide au cours de l'installation de cet appareil.

Votre appareil a été conçu pour que la condensation s'évapore dans des conditions normales. Cependant, en présence d'une humidité extrême, un surplus de condensation peut provoquer un débordement de la cuvette de base vers l'extérieur. L'appareil doit être installé de telle sorte que l'écoulement de la condensation ne se déverse pas sur des passants ou sur des propriétés avoisinantes.

fan speed based on the set temperature.

FAN SPEED: Select from four different fan settings;

Low Manual background , Medium Manual background , High Manual background and Auto Auto during Cool and Fan Only mode. Please note: During ‘Dry’ mode the fan speed is automatically defined .

ENERGY SAVER: Automatically cycles the fan on Manual backgroundManual backgroundManual background and off while the compressor is not in use.

TEMP. /TIMER Control: Used to increase Manual background or

decrease Manual background the Temperature setting in 1°C / °F increments.and Auto-Timer On/Off settings in 30 min./1hr. increments.

Auto

 

Auto

 

MODE

Fan

Mode

 

 

Speed

Selector

 

 

 

 

 

Power

Energy

 

Button

 

 

Saver

 

 

Choix du meilleur endroit

A. Ce climatiseur pour chambre a été conçu pour être

installé facilement dans une fenêtre à châssis à

guillotine simple ou double. Cependant, comme le

design de la fenêtre peut varier, il peut être nécessaire

d'y faire quelques modifications pour une installation

sécuritaire et appropriée.

B. Assurez-vous que la fenêtre et son châssis sont

structurellement solides et exempts de bois sec et

pourri.

C. Pour un maximum d'efficacité, installez le climatiseur

sur le côté de la maison ou de l'immeuble qui se

F.N'UTILISEZ PAS DE RALLONGES ÉLECTRIQUES « ORDINAIRES » POUR CET APPAREIL. S'il est nécessaire d'utiliser une rallonge pour brancher votre climatiseur, utilisez uniquement une rallonge approuvée pour « climatiseur » (disponible dans la plupart des magasins de quincaillerie locaux).

G.N'installez PAS l'appareil à un endroit où on soupçonne une fuite de gaz combustibles. Votre climatiseur peut tomber en panne dans une atmosphère qui contient des huiles (y compris des huiles pour machines), des gaz sulfurés, ou s'il est près de sources d'eau chaude, etc.

Note: This appliance allows you select the temperature scale to be displayed in either “Celsius” or Fahrenheit” according to your preference. To change the temperature scale displayed on the electronic display, press both the “Temp/Timer” adjust arrows simultaneously to alternate between “Celsius” & “Fahrenheit”.

Manual backgroundManual background CHECK FILTER : The adjacent indicator light will Manual background illuminate as a reminder to clean the air conditioner filter (see page 9) Once the filter has been cleaned and replaced, depress the Check Filter button in order to resume operation.

Manual backgroundManual backgroundManual background SLEEP MODE : When activated, the current set Manual backgroundManual backgroundManual background temperature is gradually increased over a one (1) hour period then maintained for seven (7) hours. Once the program is complete, the air conditioner will resume to it’s previous set temperature (before sleep mode was activated). This feature is meant to be used during the night time hours to prevent the room from getting too cold (while you sleep) and results in less compressor running time and reduced energy consumption. Sleep mode may be cancelled by depressing the Sleep Mode button while the program is running.

AUTO-TIMER:Used to Initiate the Auto On and/or Auto Off timer.

While the Air Conditioner is off (Auto-On):

1.Press the Auto-Timer button once and the adjacent Auto-On indicator light ‘ Manual background ‘ will illuminate.

2.Use the Temp/Timer control cursors to select a delayed On time of up to 24 hours.

3.Select the appropriate mode under which you want the unit to operate (Auto-Cool-Dry-Fan Only)

4.Select the fan speed setting.

5.The time you selected will appear in the LED display..

While the Air Conditioner is on (Auto-Off);

1. Press the Auto-Timer button twice and the adjacent

Auto-Off indicator light Manual background will illuminate.

2.Use the Temp/Timer control cursors to select a delayed Off time of up to 24 hours.

3.The time you selected will appear in the LED display

The Auto On and Auto Off timer can operate during the same program by defining the Auto-Off parameters immediately after the Auto On parameters.

The Auto-Timer may be cancelled at any time by turning

7the unit On/Off.

trouve plus souvent à l'ombre qu'au soleil. Si

l'appareil est directement sous les rayons du soleil, il

est recommandable d'installer un auvent pour

protéger l'unité.

D. Laissez suffisamment d'espace libre autour du

caisson pour permettre une ample circulation d'air à

travers l'appareil. Voir fig. 2. L'arrière de l'appareil

doit donner sur l'extérieur de la maison et non pas

dans un garage ou à l'intérieur d'un immeuble. Tenez

l'appareil aussi loin que possible de tout obstacle ou

obstruction et à au moins 30 po au-dessus du

plancher ou du sol. Il ne faut pas que les rideaux ou

d'autres objets à l'intérieur de la pièce puissent

bloquer le flux d'air.

E. Assurez-vous que la prise électrique appropriée se

trouve à la portée de l'installation. N'utilisez qu'un

circuit à prise unique calculé à 15 ampères. Tout le

câblage doit être conforme aux codes électriques

locaux et nationaux.

 

 

 

Auvent

 

20 po

 

 

 

min.

 

 

 

 

 

12 pi min.

 

 

 

20 po

 

 

 

min.

 

 

30 po

Clôture,

 

Obstacle

min.

mur, ou

 

 

autre

 

latéral

 

 

 

obstacle

 

 

Sol

Fig. 2

 

 

 

 

 

16

Page 8