Danby dac10007ee, DAC8007EE, DAC12507EE Electrical Specifications, Receptacle and Fuse Types

Models: dac12077ee DAC7077EE DAC12507EE DAC8007EE dac10007ee

1 13
Download 13 pages 9.61 Kb
Page 4
Image 4
Electrical Specifications

Electrical Specifications

1. All wiring must comply with local and national electrical codes and must be installed by a qualified electrician. If you have any questions regarding the following instructions, contact a qualified electrician.

2. Check available power supply and resolve any wiring problems BEFORE installing and operating this unit.

3. This 115V air conditioner uses 10.1 or less (depending on model) nameplate amps and may be used in any properly wired, general purpose household receptacle. See Table 1 for specifications for individual branch circuit.

4. For your safety and protection, this unit is grounded through the power cord plug when plugged into a matching wall outlet. If

you are not sure whether your wall outlet is properly grounded, please consult a qualified electrician.

5. The wall outlet (3-pin) must match the plug (3- pin) on the service cord supplied with the unit. DO NOT use plug adapters. See Table 2 for receptacle and fuse information. DO NOT USE "REGULAR" EXTENSION CORDS WITH THIS UNIT. If it is necessary to use an extension cord to connect your air conditioner, use an approved "air conditioner" extension cord only. (available at most local hardware stores)

6. The rating plate on the unit contains electrical and other technical data.

Table 1: Suggested Individual Branch Circuit

Nameplate Amps

AWG Wire Size*

4.9 to 10.1

14

AWG- American Wire Gage

* Based on copper wire at 60 °C temperature rating.

Table 2: Receptacle and Fuse Types

Rated Volts

125

Amps

15

 

 

 

 

 

Wall Outlet

 

 

 

 

 

 

 

 

 

 

 

 

 

Fuse Size

15

 

Time Delay Fuse

Plug Type

(or circuit breaker)

 

 

 

3

Page 4
Image 4
Danby dac10007ee, DAC8007EE, DAC12507EE, dac12077ee, DAC7077EE Electrical Specifications, Receptacle and Fuse Types