ELECTRICAL SPECIFICATIONS
1)All wiring must comply with local and national electrical codes and be installed by a qualified electrician. If you have any questions regarding the following instructions, contact a qualified electrician.
2)Check available power supply and resolve any wiring problems BEFORE installation and operation of this unit.
3)For your safety and protection, this unit is grounded through the power cord plug when plugged into a matching wall outlet. If you are not sure whether the wall outlets in your home are properly grounded, please consult a qualified electrician. DO NOT
USE PLUG ADAPTERS OR EXTENSION CORDS.
4)The manufacturers nameplate is located on the rear wall of the water tank compartment. The nameplate contains electrical and other technical data specific to this unit.
5)To avoid the possibility of personal injury, always disconnect the power supply before attempting to clean and/or service the unit.
UNIT SPECIFICATIONS
|
| Model Number: | DDR2509EE | DDR3009EE | DDR4009EE |
| |
|
|
|
|
|
|
|
|
|
| Dehumidifying Capacity (Pints / Liters) | 25 / 11.8 | 30 / 14.2 | 40 / 18.9 |
|
|
|
| Electrical Requirements | 115 Volts / 60 Hz | 115 volts / 60 Hz | 115 volts / 60 Hz |
| |
|
| Power Input (Watts) | 380 | 420 | 525 |
|
|
|
| Rated Amperage (Dehumidifying) | 3.8 | 4.2 | 4.8 |
|
|
|
| Air Flow Circulation- High Fan Speed |
|
|
|
|
|
|
| (Cubic Feet per Minute) | 180 | 180 | 180 |
|
|
|
| Type of Refrigerant | R22 | R22 | R22 |
| |
|
| Water Tank Capacity (Pints / Liters) | 5 / 10.55 | 5 / 10.55 | 5 / 10.55 |
|
|
|
| Operating Noise Level (dB A) | 52 | 52 | 54 |
|
|
|
| Unit Dimensions (Width x Height x Depth) | 13 6/16 x 19 15/16 x 10 | 13 6/16 x 19 15/16 x 10 | 13 6/16 x 19 15/16 x10 |
| |
|
| Net Weight (kg / lbs) | 15 / 33.1 | 15 / 33.1 | 15 / 33.1 |
|
|
|
|
|
|
|
|
|
|
NOTE: Specifications are subject to change without notice, for further improvements.