Window / Patio Door Kit Installation
(Air Conditioning Mode ONLY)
Your window kit has been designed to fit most standard “vertical” / “horizontal” windows and patio doors up to a maximum height of 80”. For vertical window and/or patio door applications, lock positions are provided in each slider sction. Wing nuts are also provided to secure the sections togethor (see Fig. 5a).
Rain Hood Assembly
1)Fold both sides of the Rain Hood 90° as so the flanges are facing outward. Fig 1
2)Slide the Rain Hood
flanges onto the edges of the slider kit until it is
lined up with the intake
vent (shown in Fig 2). Once the mounting holes on the slider, as well as the Rain Hood are aligned, secure the Rain Hood to the slider with the four mounting screws provided.
Rain Hood is to be installed only over air intake vent
RainSlider kit
Hood |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Intake hose |
Fig. 2 |
|
| adapter | ||||
|
|
| |||||
|
|
|
|
|
|
|
|
IMPORTANT:
•For horizontal window kit applications refer to figure 3a for correct Rain Hood insert positioning.
•For vertical window kit applications (including patio) refer to figure 4a for correct Rain Hood insert positioning.
1) Select a suitable location,making sure you have |
access to an electrical outlet. |
2) Install both flexible hoses to the rear side of the |
unit. Both hoses are identical and can be installed |
into either opening. Insert the hose collar with the 2 |
lock tabs into the 2 slots on the top of each |
Horizontal Window
Window Slider Kit
Minimum: 28" (71.1 cm)Fig. 3
Maximum: 48 3/8" (123 cm)
Rain hood inserts are
|
| A | installed in “A” and “B” |
|
|
| |
| C |
| postions with vent open- |
|
| ing facing down (C) | |
Fig. 3a |
|
| |
| B |
| |
|
|
|
Vertical
Window
Fig.4
Window Slider Kit
Minimum: 28" (71.1 cm)
Maximum: 48 3/8" (123 cm)
Fig.4a
Rain hood inserts are | A | |
installed in “A” and “C” | C | |
positions with vent open- | ||
| ||
ing facing down (B) |
|
B
Please Note: In a vertical application, the exhaust hose MUST be positioned above the intake hose in the window slider. See Fig 5. This will avoid having the exhaust heat go through the intake and back into the unit.
opening and twist to lock into position. |
3) Install the adjustable Window/Patio Door Slider |
Kit as required. Fig’s. 3, 4, 5. |
4) Install the window exhaust adapters into the |
openings in the slider section, making sure the |
window slider sections are secure. |
Important:: Ensure the exhaust adapter labeled “air intake” is installed on the hose that is connected to the air intake opening on the back of the unit.
Patio
Door
Air exhaust
Air intake
Fig. 5
Fig.
Patio Door Kit Minimum: 28" (71.1 cm) Maximum: 80" (203 cm)